Passive radiofrequency x-ray dosimeter tag based on flexible radiation-sensitive oxide field-effect transistor.

Cramer Tobias, Fratelli Ilaria, Barquinha Pedro, Santa Ana, Fernandes Cristina, D'Annunzio Franck, Loussert Christophe, Martins Rodrigo, Fortunato Elvira, Fraboni Beatrice

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Distributed x-ray radiation dosimetry is crucial in diverse security areas with significant environmental and human impacts such as nuclear waste management, radiotherapy, or radioprotection devices. We present a fast, real-time dosimetry detection system based on flexible oxide thin-film transistors that show a quantitative shift in threshold voltage of up to 3.4 V/gray upon exposure to ionizing radiation. The transistors use indium-gallium-zinc-oxide as a semiconductor and a multilayer dielectric based on silicon oxide and tantalum oxide. Our measurements demonstrate that the threshold voltage shift is caused by the accumulation of positive ionization charge in the dielectric layer due to high-energy photon absorption in the high-Z dielectric. The high mobility combined with a steep subthreshold slope of the transistor allows for fast, reliable, and ultralow-power readout of the deposited radiation dose. The order-of-magnitude variation in transistor channel impedance upon exposure to radiation makes it possible to use a low-cost, passive radiofrequency identification sensor tag for its readout. In this way, we demonstrate a passive, programmable, wireless sensor that reports in real time the excess of critical radiation doses.

Для цитирования: Cramer Tobias, Fratelli Ilaria, Barquinha Pedro, Santa Ana, Fernandes Cristina, D'Annunzio Franck, Loussert Christophe, Martins Rodrigo, Fortunato Elvira, Fraboni Beatrice. Passive radiofrequency x-ray dosimeter tag based on flexible radiation-sensitive oxide field-effect transistor.. Science advances. 2018. DOI: 10.1126/sciadv.aat1825.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.