Radiation exposure to the surgeon during minimally invasive spine procedures is directly estimated by patient dose.

Harrison Farber S, Nayar Gautam, Desai Rupen, Reiser Elizabeth W, Byrd Sarah A, Chi Deborah, Idler Cary, Isaacs Robert E

СтатьяПеревод в очереди

Аннотация

PURPOSE: Radiation exposure is a necessary component of minimally invasive spine procedures to augment limited visualization of anatomy. The surgeon's exposure to ionizing radiation is not easily recognizable without a digital dosimeter-something few surgeons have access to. The aim of this study was to identify an easy alternative method that uses the available radiation dose data from the C-arm to accurately predict physician exposure.

METHODS

The senior surgeon wore a digital dosimeter during all minimally invasive spine fusion procedures performed over a 12-month period. Patient demographics, procedure information, and radiation exposure throughout the procedure were recorded.

RESULTS

Fifty-five minimally invasive spine fusions utilizing 330 percutaneous screws were included. Average radiation dose was 0.46 Rad/screw to the patient. Average radiation exposure to the surgeon was 1.06 ± 0.71 μSv/screw, with a strong positive correlation (r = 0.77) to patient dose. The coefficient of determination (r2) was 0.5928, meaning almost two-thirds of the variability in radiation exposure to the surgeon is explained by radiation exposure to the patient.

CONCLUSIONS

Intra-operative radiation exposure to the patient, which is easily identifiable as a continuously updated fluoroscopic monitor, is a reliable predictor of radiation exposure to the surgeon during percutaneous screw placement in minimally invasive spinal fusion surgery and therefore can provide an estimate of exposure without the use of a dosimeter. With this, a surgeon can better understand the magnitude of their exposure on a case-by-case basis rather than on a quarterly basis, or more likely, not at all. These slides can be retrieved under Electronic Supplementary Material.

Для цитирования: Harrison Farber S, Nayar Gautam, Desai Rupen, Reiser Elizabeth W, Byrd Sarah A, Chi Deborah, Idler Cary, Isaacs Robert E. Radiation exposure to the surgeon during minimally invasive spine procedures is directly estimated by patient dose.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2018. DOI: 10.1007/s00586-018-5653-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.