MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2214/ajr.17.18296

Медицинская библиотека · AJR. American journal of roentgenology · 2017

Prospective Comparison of Standard- Versus Low-Radiation-Dose CT Enterography for the Quantitative Assessment of Crohn Disease.

Rosenfeld Greg, Brown Jacqueline, Vos Patrick M, Leipsic Jonathon, Enns Robert, Bressler Brian

Сравнительное исследованиеСтатьяEquivalence TrialПеревод в очереди

Аннотация

OBJECTIVE

CT enterography (CTE) is sensitive and specific for active inflammatory changes of Crohn disease (CD), but its use has been limited by exposure to ionizing radiation. The objective of this study is to show the noninferiority of a model-based iterative reconstruction (MBIR) technique using lower radiation doses compared with standard-dose CTE in the assessment of CD.

SUBJECTS AND

METHODS

Patients referred to a hospital radiology department for CTE for the evaluation of CD underwent both a standard examination (used to generate filtered back-projection and adaptive statistical iterative reconstruction [ASIR] images) and low-dose MBIR CTE performed in a random sequence on the same day. Images were reviewed by two radiologists for signs of small-bowel CD. Radiologic findings obtained using ASIR and clinical assessments of disease activity served as the reference standard for comparison with low-dose CTE findings.

RESULTS

A total of 163 patients, 92 (56.4%) of whom had active disease, underwent CTE. MBIR was found to be noninferior to the two standard-dose techniques, with no significant differences noted between the three types of images when compared with the clinical reference standard. As compared with the radiologic standard of ASIR, the very-low-dose scans had a high degree of accuracy, with sensitivity ranging from 0.85 to 0.94 and specificity ranging from 0.84 to 0.97 depending on the reader. A significant reduction in radiation exposure was noted with MBIR (mean [± SD] reduction, 3.30 ± 3.17 mSv) versus standard-dose imaging (7.16 ± 4.61 mSv; p < 0.001).

CONCLUSION

Low-dose CTE using MBIR is sensitive and specific for the detection of active inflammatory changes of CD while utilizing radiation doses substantially lower than those associated with standard techniques.

Для цитирования: Rosenfeld Greg, Brown Jacqueline, Vos Patrick M, Leipsic Jonathon, Enns Robert, Bressler Brian. Prospective Comparison of Standard- Versus Low-Radiation-Dose CT Enterography for the Quantitative Assessment of Crohn Disease.. AJR. American journal of roentgenology. 2017. DOI: 10.2214/ajr.17.18296.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.