Accuracy of coronary artery calcium scoring with tube current reduction by 75%, using an adaptive iterative reconstruction algorithm.

Luhur Reny, Schuijf Joanne D, Mews Jürgen, Blobel Jörg, Hamm Bernd, Lembcke Alexander

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To assess the accuracy of an iterative reconstruction (IR) technique for coronary artery calcium scoring with reduced radiation dose.

METHODS

163 consecutive patients underwent twofold scanning by 320-row detector CT at 120 kVp. A low-dose scan at 25% tube current but with standard scan length (14 cm) was followed by a standard dose scan with routine tube current but reduced scan length (10 cm). Reduced dose images were constructed using filtered back-projection (FBP) and IR (adaptive iterative dose reduction in three dimensions). The standard dose scan reconstructed with FBP served as the gold standard for comparisons. Image noise and Agatston coronary calcium scores were determined and compared between the groups.

RESULTS

Compared with FBP at standard dose, noise at reduced dose increased markedly with FBP but remained low with IR. Mean Agatston score with FBP at reduced dose showed a significant increase as compared with FBP at standard dose. No significant difference was observed when applying IR at reduced dose. At reduced dose, 38 (23.3%) patients were reassigned to a different cardiovascular risk category with FBP but only 8 (4.9%) with IR. Out of 47 patients with a zero Agatston score, 15 patients (31.9%) were false-positive with FBP at reduced dose, but no false positives were found with IR.

CONCLUSION

IR allows accurate coronary artery calcium scoring with a radiation dose reduced by 75%. Advances in knowledge: The application of adaptive iterative dose reduction in three dimensions allows the maintenance of accurate Agatston scores and risk stratification at significantly reduced tube current, thus reducing the patient's exposure to ionizing radiation.

Для цитирования: Luhur Reny, Schuijf Joanne D, Mews Jürgen, Blobel Jörg, Hamm Bernd, Lembcke Alexander. Accuracy of coronary artery calcium scoring with tube current reduction by 75%, using an adaptive iterative reconstruction algorithm.. The British journal of radiology. 2018. DOI: 10.1259/bjr.20170678.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.