Persiani P, Gurzi M, Moreschini O, Di Giacomo G, Villani C
Аннотация
PURPOSE: The current techniques used to lock distal screws for the nailing of long bone fractures expose the surgeons, radiologists and patients to a hearty dose of ionizing radiation. The Sureshot™ Distal Targeting System is a new technique that, with the same results, allows for shorter surgery times and, consequently, less exposure to radiation.
MATERIALS AND METHODS: The study was performed on 59 patients (34 males and 25 females) with a simple humerus fracture diagnosis, type 1.2.A according to the AO classification, who were divided into two groups. Group 1 was treated with ante-grade intramedullary nailing with distal locking screws inserted with a freehand technique. Group 2 was treated with the intramedullary nail using the Sureshot™ Distal Targeting System. Two intra-operative time parameters were evaluated in both groups: the time needed for the positioning of the distal locking screws and the time of exposure to ionizing radiations during this procedure.
RESULTS: Group 2 showed a lower average distal locking time compared to group 1 (645.48″ vs. 1023.57″) and also a lower average time of exposure to ionizing radiation than in group 1 (4.35″ vs. 28.96″).
CONCLUSION: The Sureshot™ Distal Targeting System has proven to be equally effective when compared to the traditional techniques, with the added benefits of a significant reduction in both surgical time and risk factors related to the exposure to ionizing radiation for all the operating room staff and the patient.
MATERIALS AND METHODS: The study was performed on 59 patients (34 males and 25 females) with a simple humerus fracture diagnosis, type 1.2.A according to the AO classification, who were divided into two groups. Group 1 was treated with ante-grade intramedullary nailing with distal locking screws inserted with a freehand technique. Group 2 was treated with the intramedullary nail using the Sureshot™ Distal Targeting System. Two intra-operative time parameters were evaluated in both groups: the time needed for the positioning of the distal locking screws and the time of exposure to ionizing radiations during this procedure.
RESULTS: Group 2 showed a lower average distal locking time compared to group 1 (645.48″ vs. 1023.57″) and also a lower average time of exposure to ionizing radiation than in group 1 (4.35″ vs. 28.96″).
CONCLUSION: The Sureshot™ Distal Targeting System has proven to be equally effective when compared to the traditional techniques, with the added benefits of a significant reduction in both surgical time and risk factors related to the exposure to ionizing radiation for all the operating room staff and the patient.