MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4070/kcj.2015.45.6.451

Медицинская библиотека · Korean circulation journal · 2015

Radiation Exposure in Coronary Angiography: A Comparison of Cineangiography and Fluorography.

Hwang Jongmin, Lee Soo Yong, Chon Min Ku, Lee Sang Hyun, Hwang Ki Won, Kim Jeong Su, Park Yong Hyun, Kim June Hong, Chun Kook Jin

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

Coronary angiography (CAG) is the gold standard for diagnosing coronary artery disease. However, exposure to ionizing radiation delivered during CAG has various negative biological effects on humans. In this study, there was an evaluation of whether fluorography resulted in decreased radiation exposure, as compared with cineangiography.

SUBJECTS AND

METHODS

Fifty-five patients were prospectively enrolled and divided into two CAG groups, in accordance with the operator's professional discretion: a conventional cineangiography group versus a fluorography group. Fluorography refers to the photography of fluoroscopic images that are retrospectively stored, e.g., using the "Store fluoro" function of the Siemens cardiac angiography system. The primary outcomes included the air kinetic energy released per unit mass {air kerma (AK) mGy} and the dose (kerma)-area product (DAP; µGy · m(2)), both measured using built-in software in the Siemens system. The secondary outcomes included the total procedure time and amount of contrast agent used with each CAG method.

RESULTS

The total AK and DAP were significantly lower in the fluorography group (159.3±64.9 mGy and 1337.9±629.6 µGy · m(2), respectively) than in the cineangiography group (326.9±107.5 mGy and 2341.1±849.9 µGy · m(2), respectively; p=0.000 for both). The total procedure time (cineangiography vs. fluorography, 12.8±4.7 vs. 12.5±2.9 min; p=0.779) and contrast agent amount (136.1±28.3 vs. 126.3±25.7, p=0.214) were comparable between the two groups.

CONCLUSION

Fluorography is a useful method to decrease the radiation exposure in selected patients requiring CAG.

Для цитирования: Hwang Jongmin, Lee Soo Yong, Chon Min Ku, Lee Sang Hyun, Hwang Ki Won, Kim Jeong Su, Park Yong Hyun, Kim June Hong, Chun Kook Jin. Radiation Exposure in Coronary Angiography: A Comparison of Cineangiography and Fluorography.. Korean circulation journal. 2015. DOI: 10.4070/kcj.2015.45.6.451.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.