Thaker Ashesh, Navadeh Soodabeh, Gonzales Hugo, Malekinejad Mohsen

Аннотация

PURPOSE: The use of medical imaging has expanded greatly in the past three decades, raising concern about potential unwanted carcinogenic harms associated with exposure to ionizing radiation among patients. This study summarizes evidence of efficacy of interventions that have prompted policies, and structural-level interventions aimed at reducing radiation dose and risk of cancer, especially among women.

METHODS: Using standard terms, we conducted searches in MEDLINE, Scopus, and Web of Science, and de-duplicated retrieved citations. We hand-searched the reference section of eligible studies and contacted radiology experts to identify studies missed from electronic searches. Two reviewers screened retrieved citations based on predefined eligibility criteria, to identify relevant studies, extract key information from each, rate the quality of evidence, and summarize data in tabular and graphical format.

RESULTS: From a total of 1,543 unique citations identified from all sources, 16 were included for data extraction. Half of the studies focused on reduction of ionizing exposure from CT, and half on x-ray or fluoroscopy. Identified interventions were broadly categorized as: policy or structural intervention (two; 13%); multipronged (four; 25%); dose-feedback system (five; 31%); provision of training (four; 25%); and quality-control audit (one; 6%). In general, multipronged programs had a higher range for dose reduction (22%-74%), followed by policy/structural interventions (37%-50%).

CONCLUSIONS: Existing evidence on the effectiveness of policies aimed at reducing patient radiation dose is disperse and low in quality. Compared with other approaches, multipronged efforts may offer more patient protection.