OBJECTIVES

The purpose of this study was to describe radiation exposure from cardiac imaging procedures over time in a general population.

BACKGROUND

Cardiac imaging procedures frequently expose patients to ionizing radiation, but their contribution to effective doses of radiation in the general population is unknown.

METHODS

We used administrative claims to identify cardiac imaging procedures performed from 2005 to 2007 in 952,420 nonelderly insured adults in 5 U.S. health care markets. We estimated 3-year cumulative effective doses of radiation in millisieverts from these procedures We then calculated population-based annual rates of radiation exposure to effective doses < or =3 mSv/year (background level of radiation from natural sources), >3 to 20 mSv/year, or >20 mSv/year (upper annual limit for occupational exposure averaged over 5 years).

RESULTS

A total of 90,121 (9.5%) individuals underwent at least 1 cardiac imaging procedure using radiation. Among patients who underwent > or =1 cardiac imaging procedures, the mean cumulative effective dose over 3 years was 23.1 mSv (range 1.5 to 543.7 mSv). Myocardial perfusion imaging accounted for 74% of the cumulative effective dose. Overall, 47.8% of cardiac imaging procedures were performed in physician offices; this proportion was higher for myocardial perfusion imaging (74.8%) and cardiac computed tomography studies (76.5%). The annual population-based rate of receiving an effective dose of >3 to 20 mSv/year was 89.0 per 1,000; and 3.3 per 1,000 for cumulative doses >20 mSv/year. Annual effective doses increased with age and were generally higher among men.

CONCLUSIONS

Cardiac imaging procedures lead to substantial radiation exposure and effective doses for many patients in the U.S.

Для цитирования: Chen Jersey, Einstein Andrew J, Fazel Reza, Krumholz Harlan M, Wang Yongfei, Ross Joseph S, Ting Henry H, Shah Nilay D, Nasir Khurram, Nallamothu Brahmajee K. Cumulative exposure to ionizing radiation from diagnostic and therapeutic cardiac imaging procedures: a population-based analysis.. Journal of the American College of Cardiology. 2010. DOI: 10.1016/j.jacc.2010.05.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.