MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ehjdh/ztac008

Медицинская библиотека · European heart journal. Digital health · 2022

Heartbeat tracking task performance, an indicator of interoceptive accuracy, is associated with improvement of exercise tolerance in patients undergoing home-based cardiac rehabilitation.

Miyazaki Shinjiro, Kanbara Kenji, Kunikata Jun, Tobiume Atsushi, Hayashino Shusei, Namba Tsunetatsu, Matsumoto Ichiro, Takagi Yuichiro, Minamino Tetsuo

СтатьяПеревод в очереди

Аннотация

AIMS: Interoception is the sensing function of physiological conditions and is crucial in self-regulation and decision-making. We examined the association of heartbeat tracking task performance, an indicator of interoceptive accuracy, with the degree of improvement in exercise tolerance in patients undergoing home-based cardiac rehabilitation.

METHODS AND

RESULTS

Participants underwent baseline peak oxygen uptake (VO2) measurements and a heartbeat tracking task. The heartbeat tracking task score varies between 0 and 1, with higher scores indicating a better heartbeat perception. After 6 months of home-based exercise training, peak VO2 was measured again, and the percentage change (%Δ peak VO2) relative to the peak VO2 at baseline was calculated. Univariate regression analysis was performed to examine the association between %Δ peak VO2 and the heartbeat tracking task score. Multiple regression analysis was performed to determine the predictors of %Δ peak VO2. Of 120 participants, 100 patients (age 65.9 ± 11.9 years; 86% male) were included. There was a significant positive association between %Δ peak VO2 and the heartbeat tracking task score at baseline (R 2 = 0.236, P < 0.001). In multiple regression analysis, the percentage of measured peak VO2 to the predicted value (%predicted peak VO2) (β = -0.248, P = 0.002), exercise adherence (β = 0.364, P < 0.001), and heartbeat tracking task score at baseline (β = 0.372, P < 0.001) were significantly associated with %Δ peak VO2.

CONCLUSIONS

Heartbeat tracking task performance, an indicator of interoceptive accuracy, at baseline is associated with the degree of improvement in exercise tolerance.

Для цитирования: Miyazaki Shinjiro, Kanbara Kenji, Kunikata Jun, Tobiume Atsushi, Hayashino Shusei, Namba Tsunetatsu, Matsumoto Ichiro, Takagi Yuichiro, Minamino Tetsuo. Heartbeat tracking task performance, an indicator of interoceptive accuracy, is associated with improvement of exercise tolerance in patients undergoing home-based cardiac rehabilitation.. European heart journal. Digital health. 2022. DOI: 10.1093/ehjdh/ztac008.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.