Медицинская библиотека · Journal of cardiovascular electrophysiology · 2022

Association between implantable defibrillator-detected sleep apnea and atrial fibrillation: The DASAP-HF study.

Boriani Giuseppe, Diemberger Igor, Pisanò Ennio C L, Pieragnoli Paolo, Locatelli Alessandro, Capucci Alessandro, Talarico Antonello, Zecchin Massimo, Rapacciuolo Antonio, Piacenti Marcello, Indolfi Ciro, Arias Miguel A, Checchinato Catia, La Rovere Maria T, Sinagra Gianfranco, Emdin Michele, Ricci Renato P, D'Onofrio Antonio

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

INTRODUCTION

The Respiratory Disturbance Index (RDI) computed by an implantable cardioverter defibrillator (ICD) algorithm accurately identifies severe sleep apnea (SA). In the present analysis, we tested the hypothesis that RDI could also predict atrial fibrillation (AF) burden.

METHODS

Patients with ejection fraction ≤35% implanted with an ICD were enrolled and followed up for 24 months. One month after implantation, patients underwent a polysomnographic study. The weekly mean RDI value was considered, as calculated during the entire follow-up period and over a 1-week period preceding the sleep study. The endpoints were as follows: daily AF burden of ≥5 min, ≥6 h, ≥23 h.

RESULTS

Here, 164 patients had usable RDI values during the entire follow-up period. Severe SA (RDI ≥ 30 episodes/h) was diagnosed in 92 (56%) patients at the time of the sleep study. During follow-up, AF burden ≥ 5 min/day was documented in 70 (43%), ≥6 h/day in 48 (29%), and ≥23 h/day in 33 (20%) patients. Device-detected RDI ≥ 30 episodes/h at the time of the polygraphy, as well as the polygraphy-measured apnea hypopnea index ≥ 30 episodes/h, were not associated with the occurrence of the endpoints, using a Cox regression model. However, using a time-dependent model, continuously measured weekly mean RDI ≥ 30 episodes/h was independently associated with AF burden ≥ 5 min/day (hazard ratio [HR]: 2.13, 95% confidence interval [CI]: 1.24-3.65, p = .006), ≥6 h/day (HR: 2.75, 95% CI: 1.37-5.49, p = .004), and ≥23 h/day (HR: 2.26, 95% CI: 1.05-4.86, p = .037).

CONCLUSIONS

In heart failure patients, ICD-diagnosed severe SA on follow-up data review identifies patients who are from two- to three-fold more likely to experience an AF episode, according to various thresholds of daily AF burden.

Для цитирования: Boriani Giuseppe, Diemberger Igor, Pisanò Ennio C L, Pieragnoli Paolo, Locatelli Alessandro, Capucci Alessandro, Talarico Antonello, Zecchin Massimo, Rapacciuolo Antonio, Piacenti Marcello, Indolfi Ciro, Arias Miguel A, Checchinato Catia, La Rovere Maria T, Sinagra Gianfranco, Emdin Michele, Ricci Renato P, D'Onofrio Antonio. Association between implantable defibrillator-detected sleep apnea and atrial fibrillation: The DASAP-HF study.. Journal of cardiovascular electrophysiology. 2022. DOI: 10.1111/jce.15506.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.