m+Medelevator.RU
← Поиск публикаций
Pacing and clinical electrophysiology : PACE · 2021

Outcome of left atrial appendage closure using cerebral protection system for thrombosis: no patient left behind.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Limite Luca Rosario, Radinovic Andrea, Cianfanelli Lorenzo, Altizio Savino, Peretto Giovanni, Frontera Antonio, D'Angelo Giuseppe, Baratto Francesca, Marzi Alessandra, Ancona Francesco, Ingallina Giacomo, Capogrosso Cristina, Stella Stefano, Melillo Francesco, Agricola Eustachio, Della Bella Paolo, Mazzone Patrizio

Аннотация

BACKGROUND: Left atrial appendage (LAA) thrombosis increases the risk of stroke and its management has to be assessed. The aim of the present study is to evaluate short and long-term safety and efficacy of a standardized approach of percutaneous LAA closure (LAAC) routinely using a cerebral protection device (CPD) in patients with LAA thrombosis or sludge (LAAT).

METHODS: We prospectively enrolled 14 consecutive patients with atrial fibrillation complicated by LAAT presenting in a high-volume tertiary center. In seven patients (50%) LAAT was found after anticoagulant withdrawal for severe bleedings and in the remaining half LAAT was found despite appropriate anticoagulant therapy. All patients were treated with a standardized interventional approach of LAAC routinely using a CPD and guided by transoesophageal echocardiography.

RESULTS: Mean age was 68 ± 14 years and nine patients (64%) were male. Mean CHA2 DS2 -VASc and HAS-BLED scores were 3.3 ± 1.6 and 2.3 ± 1.1, respectively. Six patients (42.8%) presented organized thrombi while eight LAA sludge (57.1%). In 13 patients (92.8%) CPD was positioned through a right radial arterial access. Procedural success was achieved in all patients. In one patient we assisted to embolization of the thrombus during deployment of the device in the absence of neurological consequences. During a mean follow up of 426 ± 307 days, one patient died for non-cardiac cause while no embolic event or major bleeding were reported.

CONCLUSION: In an unselected cohort, LAAC with the systematic use of CPD was a feasible, safe and effective therapeutic option for LAAT both acutely and after long-term follow-up.