m+Medelevator.RU
← Поиск публикаций
International journal of cardiology · 2021

Characteristics and reference values for cardiopulmonary exercise testing in the adult Chinese population - The Xiangya hospital exercise testing project (the X-ET project).

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Dun Yaoshan, Olson Thomas P, Li Cui, Qiu Ling, Fu Siqian, Cao Zeng, Ripley-Gonzalez Jeffrey W, You Baiyang, Li Qiuxia, Deng Lihua, Li Qingfang, Liu Suixin

Аннотация

BACKGROUND: Reference values of cardiopulmonary exercise testing (CPX) vary with race/ethnicity. Chinese Americans are the fastest-growing racial/ethnic group in the United States. However, there is limited information about the reference values of cardiopulmonary exercise testing (CPX) variables in the Chinese population.

METHODS: As part of the Xiangya Hospital Exercise Testing project (the X-ET project), this cross-sectional study screened 20,696 consecutive CPXs performed by 17,802 unique individuals at Xiangya Hospital of Central South University, China, from January 1, 2002, to December 31, 2019. A total of 964 unique healthy adults/tests (42% female) aged 49 ± 12 who completed a maximal ramp incremental CPX with cycle ergometry were included in this study. The reference values of primary CPX variables were expressed as the lower limit or upper limit of normal. Stepwise linear regression was used to fit the equations of key CPX variables. Predictive accuracy analysis for the equations with a comparison between present and previous studies were performed.

RESULTS: Peak oxygen consumption (V̇O2), carbon dioxide production, ventilation/min, work rate, and V̇O2 at the anaerobic threshold were regressed on age, height, weight, and sex. These predictive equations showed good in- and out-sample predictive accuracy. Comparison with prior research revealed that prediction equations of peak V̇O2 resultant from studies in which populations were entirely or primarily Caucasian had overestimated our subjects' actual values.

CONCLUSION: The reference values and predicted equations of CPX variables in this study may provide a more appropriate framework to interpret the response to maximal ramp incremental cycle ergometry in the Chinese adult population.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты