MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.msec.2016.07.033

Медицинская библиотека · Materials science & engineering. C, Materials for biological applications · 2016

Light output from six battery operated dental curing lights.

Shimokawa Carlos Alberto Kenji, Turbino Míriam Lacalle, Harlow Jessie Eudora, Price Hannah Louise, Price Richard Bengt

СтатьяПеревод в очереди

Аннотация

Light Curing Units (LCUs) are used daily in almost every dental office to photocure resins, but because the light is so bright, the user is unable to tell visually if there are any differences between different LCUs. This study evaluated the light output from six dental LCUs: Elipar Deep Cure-S (3M ESPE), Bluephase G2 (Ivoclar Vivadent), Translux 2Wave (Heraeus Kulzer), Optilight Prime (Gnatus), Slim Blast (First Medica) and Led.B (Guilin Woodpecker) with a fully charged battery, after 50, and again after 100, 20second light exposures. For each situation, the radiant power was measured 10 times with a laboratory-grade power meter. Then, the emission spectrum was measured using a fiber-optic spectrometer followed by an analysis of the light beam profile. It was found there were significant differences in the LCU power and the irradiance values between the LCUs (p<0.01). The Optilight Prime and Slim Blast LCUs showed a significant reduction in light output after a 50 and 100 exposures, while Bluephase G2 exhibited a significant reduction only after 100 exposures (p<0.01). The Bluephase G2 and Translux 2Wave delivered an emission spectrum that had two distinct wavelength emission peaks. Only the Elipar Deep Cure-S and Bluephase G2 LCUs displayed homogeneous light beam profiles, the other LCUs exhibited highly non-homogeneous light beam profiles. It was concluded that contemporary LCUs could have very different light output characteristics. Both manufacturers and researchers should provide more information about the light output from LCUs.

Для цитирования: Shimokawa Carlos Alberto Kenji, Turbino Míriam Lacalle, Harlow Jessie Eudora, Price Hannah Louise, Price Richard Bengt. Light output from six battery operated dental curing lights.. Materials science & engineering. C, Materials for biological applications. 2016. DOI: 10.1016/j.msec.2016.07.033.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.