Comparison of Aqueous Humor Nitric Oxide Levels After Different Corneal Collagen Cross-Linking Methods.

Yuksel Nilay, Ozel-Turkcu Ummuhani, Yalinbas Duygu, Novruzlu Sahin, Bilgihan Ayse, Bilgihan Kamil

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: Nitric oxide production can cause either apoptotic or necrotic cell death through oxidative stress. We aimed to investigate the nitrite oxide metabolites (NOx) and nitrite levels in the aqueous humor of rabbit eyes after different methods of corneal collagen cross-linking (CXL).

MATERIALS AND

METHODS

Twenty-four eyes of 12 adult New Zealand rabbits were used. They were assigned into four groups, each including six eyes. Group 1 (control) consisted of eyes with no treatment. Group 2 received UV-A power setting at 3 mW/cm2 for 30 minutes of continuous exposure and named as standard CXL group. Group 3 received UV-A power setting at 30 mW/cm2 for 3 minutes of continuous exposure and named as accelerated CXL (A-CXL) group. Group 4 received UV-A power setting at 30 mW/cm2 for 6 minutes of pulsed exposure (1 sec on, 1 sec off) and named as pulse-light accelerated CXL (PLA-CXL). Aqueous humors were aspirated from anterior chamber with a 27G needle after 1 hour UV-A exposure. NOx and nitrite levels were measured

Results

The nitrite levels in aqueous humor were significantly increased in Group 2 and Group 3 when compared with Group 1 (p = 0.000, p = 0.036, respectively). When treatment modalities were compared with each other, high nitrite level in Group 2 was statistically significant when compared with Group 4 (p = 0.019). NOx levels were higher in Group 2 when compared with Group 1 (p = 0.006).

CONCLUSIONS

Numerous studies investigated the physiological and pathophysiological roles of NO. NO is considered one of the most important molecule for ocular health. According to NOx level in aqueous humor, it seems that PLA-CXL is the safest method due to the similar results with control group.

Для цитирования: Yuksel Nilay, Ozel-Turkcu Ummuhani, Yalinbas Duygu, Novruzlu Sahin, Bilgihan Ayse, Bilgihan Kamil. Comparison of Aqueous Humor Nitric Oxide Levels After Different Corneal Collagen Cross-Linking Methods.. Current eye research. 2016. DOI: 10.3109/02713683.2016.1139726.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.