MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jat.3161

Медицинская библиотека · Journal of applied toxicology : JAT · 2015

Acute and subchronic toxicity of 20  kHz and 60  kHz magnetic fields in rats.

Nishimura Izumi, Oshima Atsushi, Shibuya Kazumoto, Mitani Takashi, Negishi Tadashi

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Despite increasing use of intermediate frequency (IF) magnetic fields (MFs) in occupational and domestic settings, scientific evidence necessary for health risk assessments of IF MF is insufficient. Male and female Crl:CD(SD) rats (12 per sex per group) were exposed to 20 kHz, 0.20 mT(root mean square, rms) or 60 kHz, 0.10 mT(rms) sinusoidal MFs for 22 h day(-1) for 14 days (acute) or 13 weeks (subchronic). Experiments were duplicated for each frequency to ensure outcome reproducibility, and examinations were blinded for quality assurance. All rats survived without significant clinical signs until the end of experiments. Some changes in body weight between the MF-exposed and control groups were observed over the course of exposure, although the directions of the changes were inconsistent and not statistically significant after subchronic exposure. There were significant differences between MF-exposed and control groups in some organ weights and parameters in hematology and clinical chemistry, but these were minor in magnitude and not repeated in duplicate experiments. Histopathological findings reflecting toxicity were sporadic. Frequencies of other findings were similar to historic data in this rat strain, and findings had no specific relationship to changes in organ weight or parameters of hematology and clinical chemistry in each animal. The changes observed throughout this study were considered biologically isolated and were attributable to chance associations rather than to MF exposure. The results, in particular the histopathological evidence, indicate an absence of toxicity in IF MF-exposed rats and do not support the hypothesis that IF MF exposure produces significant toxicity.

Для цитирования: Nishimura Izumi, Oshima Atsushi, Shibuya Kazumoto, Mitani Takashi, Negishi Tadashi. Acute and subchronic toxicity of 20  kHz and 60  kHz magnetic fields in rats.. Journal of applied toxicology : JAT. 2015. DOI: 10.1002/jat.3161.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.