Lamotte Michel X, Chimenti Sara, Deboeck Gael, Gillet Alexis, Kacelenenbogen Raymond, Strapart Jonathan, Vandeneynde Frédéric, Van Nooten Guido, Antoine Martine
Аннотация
BACKGROUND: With more than 15,000 implanted patients worldwide and a survival rate of 80% at 1-year and 59% at 5-years, left ventricular assist device (LVAD) implantation has become an interesting strategy in the management of heart failure patients who are resistant to other kinds of treatment. There are limited data in the literature on the change over time of exercise capacity in LVAD patients, as well as limited knowledge about the beneficial effects that rehabilitation might have on these patients. Therefore, the aim of our study was to evaluate the evolution of exercise capacity on a cohort of patients implanted with the same device (HeartWare©) and to analyse the potential impact of rehabilitation.
METHODS: Sixty-two patients implanted with a LVAD between June 2011 and June 2015 were screened. Exercise capacity was evaluated by cardiopulmonary exercise testing at 6 weeks, 6 and 12 months after implantation.
RESULTS: We have observed significant differences in the exercise capacity and evolution between the trained and non-trained patients. Some of the trained patients nearly normalised their exercise capacity at the end of the rehabilitation programme.
CONCLUSIONS: Exercise capacity of patient implanted with a HeartWare© LVAD increased in the early period after implantation. Rehabilitation allowed implanted patients to have a significantly better evolution compared to non-rehabilitated patients.
METHODS: Sixty-two patients implanted with a LVAD between June 2011 and June 2015 were screened. Exercise capacity was evaluated by cardiopulmonary exercise testing at 6 weeks, 6 and 12 months after implantation.
RESULTS: We have observed significant differences in the exercise capacity and evolution between the trained and non-trained patients. Some of the trained patients nearly normalised their exercise capacity at the end of the rehabilitation programme.
CONCLUSIONS: Exercise capacity of patient implanted with a HeartWare© LVAD increased in the early period after implantation. Rehabilitation allowed implanted patients to have a significantly better evolution compared to non-rehabilitated patients.