MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2015/197307

Медицинская библиотека · Oxidative medicine and cellular longevity · 2015

Physical Activity, Aerobic Capacity, and Total Antioxidant Capacity in Healthy Men and in Men with Coronary Heart Disease.

Gawron-Skarbek Anna, Chrzczanowicz Jacek, Kostka Joanna, Nowak Dariusz, Drygas Wojciech, Jegier Anna, Kostka Tomasz

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

The purpose of the study was to assess total antioxidant capacity (TAC) of blood serum in relation with habitual leisure time physical activity (LTPA) and aerobic capacity in a group of 90 men with coronary heart disease (CHD) aged 34.8-77.0 years and in 90 age-matched peers without CHD.

METHODS

Two spectrophotometric methods were applied to assess TAC: Ferric Reducing Ability of Serum (TAC-FRAS) and 2.2-diphenyl-1-picryl-hydrazyl (TAC-DPPH) tests. Aerobic capacity was expressed as physical working capacity at 85% of the maximal heart rate (PWC(85%HRmax)).

RESULTS

CHD patients had higher values of TACFRAS (1.37 ± 0.28 versus 1.27 ± 0.23 mmol FeCl2·L(-1); P < 0.05) but there were no group differences for TAC-DPPH and for uric acid (UA). Negative correlation was found between LTPA (also when calculated per kg of body mass) and TAC-DPPH in CHD patients. In CHD patients, TAC-FRAS and UA were lower in subjects with higher aerobic capacity expressed as PWC(85%HRmax/kg). Those associations were not found in healthy men.

CONCLUSIONS

We conclude that TAC of blood serum is moderately adversely related to LTPA and aerobic capacity in patients with CHD. UA, as the main determinant of serum TAC, may be partially responsible for those associations.

Для цитирования: Gawron-Skarbek Anna, Chrzczanowicz Jacek, Kostka Joanna, Nowak Dariusz, Drygas Wojciech, Jegier Anna, Kostka Tomasz. Physical Activity, Aerobic Capacity, and Total Antioxidant Capacity in Healthy Men and in Men with Coronary Heart Disease.. Oxidative medicine and cellular longevity. 2015. DOI: 10.1155/2015/197307.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.