Coordinated implementation of a conventional PCR assay to detect all Ebola and Marburg virus species in a European laboratory network.

Heimsch K C, Bleicker T, Best T D, Presser L D, Molenkamp R, Jääskeläinen A J, Milewska A, Šmahelová J, Baronti C, Pappa S, Tabain I, Cordeiro R, Marsili G, Huik K, Pinho Dos Reis V, Barzon L, Maes P, Drosten C, Corman V M

СтатьяМногоцентровое исследованиеВалидационное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Filoviruses, including Ebola and Marburg viruses, cause severe hemorrhagic fever in humans and primates. These viruses pose significant threats to public health, making rapid and sensitive detection critical for controlling outbreaks. We developed and validated a hemi-nested generic PanFilo assay to detect all Ebola virus species, Marburg viruses, and recently discovered bat filoviruses. This assay was deployed to 15 European laboratories and evaluated through testing of eight non-infectious samples.

OBJECTIVES

Laboratories were asked to determine the detection limit of positive controls and test all samples using the assay provided. The deployed assay enables direct Nanopore sequencing of PCR products, by using tagged primers during the second round of PCR. Sequencing of the samples was carried out on a voluntary basis.

RESULTS

Multicenter validation revealed a 95 % limit of detection of 5309 RNA copies/µL for Ebola, 10,273 copies/µL for Marburg, and 2145 copies/µL for Mengla virus. In an implementation quality assessment, 93.3 % (84/90) of samples containing filovirus RNA were correctly identified and 100 % (30/30) of filovirus-negative samples were correctly identified. Thirteen laboratories sequenced PCR products, with nine identifying all positive samples correctly.

CONCLUSION

The assay enables rapid and reliable detection of filoviruses, with sequencing capabilities for identifying both known and novel variants. This assay might be used for detection during the initial phase of an emerging filovirus outbreak, before a specific assay has been developed. However, our distribution across 15 laboratories revealed variability challenges due to reagents, human performance, and sequencing capacity, emphasizing the need for more training and standardization.

Для цитирования: Heimsch K C, Bleicker T, Best T D, Presser L D, Molenkamp R, Jääskeläinen A J, Milewska A, Šmahelová J, Baronti C, Pappa S, Tabain I, Cordeiro R, Marsili G, Huik K, Pinho Dos Reis V, Barzon L, Maes P, Drosten C, Corman V M. Coordinated implementation of a conventional PCR assay to detect all Ebola and Marburg virus species in a European laboratory network.. Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology. 2025. DOI: 10.1016/j.jcv.2025.105808.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.