MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/tnsre.2026.3715302

Медицинская библиотека · IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026

Generalization-Enhanced Cross-Set Upper-Limb Multi-Joint Torque Prediction via a Dual-Stream Time-Frequency Attention Network.

Yang Kai, Liu Keping, Dong Mingjie, Duan Xiaoqin, Yi Jiang, Nie Baozhen, Wang Chuang, Sun Zhongbo

СтатьяПеревод в очереди

Аннотация

Mapping surface electromyography (sEMG) to multi-joint torque is critical for active stroke rehabilitation. While compounded non-ideal factors between discontinuous exercise sets impose stringent demands on amplitude-phase robustness, synergy preservation, and noise resistance. This study designed and validated a dual-stream time-frequency attention network incorporating Luenberger observation feedback (DSA-Luen) to address the issue of sEMG pattern inconsistency arising from inter-set variations in repetitive upper-limb rehabilitation. The framework integrates DSA based on Real-Time Fast Fourier Transform (RTFFT) with a Luen-Mamba module inspired by the Luenberger observer. The former captures more robust dynamic sEMG information, while the latter utilizes output feedback for dynamic correction, effectively suppressing noise and enhancing prediction accuracy. On datasets from healthy subjects and stroke patients performing multiple upper-limb movements, DSA-Luen consistently outperforms time-domain sequence models and attention baselines. Averaged across four Degrees of Freedom (DOFs), cross-set evaluation attains NRMSE 0.130 and $\text {R}^{{2}}~0.703$ , representing a 23% reduction in NRMSE and a 36% increase in $\text {R}^{{2}}$ relative to the strongest attention baseline; cross-movement evaluation further achieves NRMSE 0.122 and $\text {R}^{{2}}~0.704$ . In stroke patient trials, DSA-Luen maintained a positive mean $\text {R}^{{2}}$ of 0.527, reduced NRMSE by approximately 30%, and increased $\text {R}^{{2}}$ by more than five times compared to the strongest baseline (Informer), while several baselines deteriorated to near-zero or negative values. These results demonstrate that the method maintains strong adaptability and robustness under complex non-ideal conditions. In clinical settings, it provides a transferable foundation for intent decoding in personalised active rehabilitation and reduces the recalibration burden.

Для цитирования: Yang Kai, Liu Keping, Dong Mingjie, Duan Xiaoqin, Yi Jiang, Nie Baozhen, Wang Chuang, Sun Zhongbo. Generalization-Enhanced Cross-Set Upper-Limb Multi-Joint Torque Prediction via a Dual-Stream Time-Frequency Attention Network.. IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society. 2026. DOI: 10.1109/tnsre.2026.3715302.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.