BACKGROUND

The pulsatile expansion of pulmonary vessels carries dynamic cardiopulmonary information that may reveal disease earlier than structural changes alone.

PURPOSE: To test (i) intra- and inter-scan repeatability of dynamic vessel metrics in healthy subjects, and (ii) whether chronic obstructive pulmonary disease (COPD) and postcapillary pulmonary hypertension (PH) exhibit disease-specific differences.

STUDY TYPE: Retrospective, multi-cohort feasibility study with repeatability sub-study.

SUBJECTS: Healthy: 29 (11 female), COPD: 52 (15 female), PH: 25 (15 female) with isolated postcapillary PH.

FIELDSTRENGTH/SEQUENCE: 1.5T, free-breathing spoiled gradient-echo sequence, TE = 0.82 ms, TR = 3 ms, flip angle = 5°.

ASSESSMENT: 2D U-Nets segmented pulmonary vessels throughout each series of 250 images. Dynamic metrics included the coefficient of variation (CV) of vessel area and CV of vessel signal. Delay between vessel signal and vessel expansion as %-of-RR-interval (SE-delay) together with the heart rate and lung area were calculated.

STATISTICAL TESTS: Repeatability: Friedman; intraclass correlation coefficient (ICC); standard error of measurement (SEM) and the minimal detectable change (MDC). Group comparisons: Kruskal-Wallis and multiple linear regression. p < 0.05 was considered significant.

RESULTS

Only the heart rate and the SE-delay presented significant changes across repetitive scans. Differences in Bland-Altman plots were evenly distributed across the range of measurements and symmetrically scattered around zero within 95% confidence intervals (mean bias 0.08%-5.12%). Across cohorts, CV vessel area and CV lung area differed significantly, showing lowest variability in COPD (2.67%; 7.03%) and highest in PH (4.58%; 16.74%). SE-delay was significantly prolonged in COPD (81.98%) compared to PH (67.20%) and healthy participants (62.97%). Cohort status (Healthy/COPD/PH) remained the strongest significant predictor for all parameters after adjustment (F-values 4.62-34.04), while age and gender had no significant influence (p > 0.391; p > 0.069).

DATA

CONCLUSION

Free-breathing lung MRI with automated vessel segmentation reveals distinct hemodynamic characteristics in COPD and PH. This method shows potential as a sensitive non-invasive tool for detection, phenotyping, and treatment monitoring in pulmonary pathology.

EVIDENCE LEVEL: 3.

TECHNICAL EFFICACY: 2.

Для цитирования: Glandorf Julian, Klein Marius M, Klimeš Filip, Kern Agilo Luitger, Gutberlet Marcel, Hohlfeld Jens M, Hoeper Marius M, Olsson Karen M, Wacker Frank, Vogel-Claussen Jens, Voskrebenzev Andreas. Analysis of Pulsatile Vessel Expansion in Healthy, COPD- and PH-Patients Using Dynamic Vessel Segmentation in Free-Breathing Lung MRI.. Journal of magnetic resonance imaging : JMRI. 2026. DOI: 10.1002/jmri.70249.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.