PURPOSE: To assess the diagnostic accuracy of forced eyelid closure test (FECT), ice pack test (IPT), repetitive nerve stimulation test (RNS), and acetylcholine receptor (AchR) antibody test in patients with suspected ocular myasthenia. To assess the clinical utility of AchR antibody test in predicting disease progression.

METHODS

Retrospective cohort study of patients diagnosed with ocular myasthenia at a South-Indian neuro-ophthalmology tertiary eye clinic. Baseline characteristics; ocular myasthenia symptoms; results of FECT, IPT, RNS, and AchR antibody test; and progression time to generalized myasthenia (GM) over 36 months from the time of diagnosis were recorded and analyzed using receiver operator curve analysis, multiple logistic regression, and Kaplan-Meier survival analysis.

RESULTS

FECT had a sensitivity of 96.7% (95% CI: 88.5-99.6) and a specificity of 75% (95% CI: 34.9-96.8). Combination of FECT and IPT, using the positivity of at least one test, increased the sensitivity to 98.3% (95% CI: 91-100), reducing the specificity to 50% (95% CI: 15.7-84.3), whereas using the positivity of both tests, we obtained a sensitivity of 71.7% (95% CI: 58.6-82.5) and a specificity of 100% (95% CI: 63.1-100). In the subset of patients with double negative RNS and AchR antibodies, the positive predictive value of combined FECT and IPT (double positive) was 100%. Patients who developed GM were more likely to have a positive AchR antibody test result (P = 0.001).

CONCLUSION

Combined FECT and IPT (double positive) has high diagnostic accuracy even among patients with normal RNS and negative AchR antibodies. Despite low sensitivity, AchR-antibody test has a significant predictive value in disease progression.

Для цитирования: Sivakumar Priya, Tagare Shivraj, Kumar Mahesh. Diagnostic accuracy and clinical utility of bed side tests versus laboratory tests in the diagnosis of ocular myasthenia.. Indian journal of ophthalmology. 2022. DOI: 10.4103/ijo.ijo_2015_21.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.