MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jbiomech.2019.109356

Медицинская библиотека · Journal of biomechanics · 2019

Concurrent validity of a wearable IMU for objective assessments of functional movement quality and control of the lumbar spine.

Beange Kristen H E, Chan Adrian D C, Beaudette Shawn M, Graham Ryan B

СтатьяПеревод в очереди

Аннотация

Inertial measurement units (IMUs) are being recognized in clinical and rehabilitation settings for their ability to assess movement-related disorders of the spine for better guidance of treatment-planning and tracking of recovery. This study evaluated the Mbientlab MetaMotionR IMUs, relative to Vicon motion capture equipment in measuring local dynamic stability of the spine (quantified using maximum finite-time Lyapunov exponent; λmax), lumbopelvic coordination (quantified using mean absolute relative phase; MARP), and intersegmental motor variability (quantified using deviation phase; DP) of lumbopelvic segments in 10 participants during 35 cycles of repetitive spine flexion-extension (FE). Intraclass correlations were strong between systems when using both the FE angle time-series and the sum of squares (SS) time-series to measure local dynamic stability (0.807 ≤ICC2,1λmax,FE ≤ 0.919; 0.738 ≤ ICC2,1λmax,SS ≤ 0.868), sagittal-plane lumbopelvic coordination (0.961 ≤ICC2,1MARP ≤ 0.963), and sagittal-plane lumbopelvic variability (0.961 ≤ICC2,1DP ≤ 0.963). It was concluded that the MetaMotionR IMUs can be reliably used for measuring features associated with spine movement quality and motor control during a repetitive FE task. Future work will assess the reliability of sensor placement, performance during multi-directional movements, and ability to discern clinical and healthy populations based on assessment of movement quality and control.

Для цитирования: Beange Kristen H E, Chan Adrian D C, Beaudette Shawn M, Graham Ryan B. Concurrent validity of a wearable IMU for objective assessments of functional movement quality and control of the lumbar spine.. Journal of biomechanics. 2019. DOI: 10.1016/j.jbiomech.2019.109356.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.