MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clinbiomech.2004.01.002

Медицинская библиотека · Clinical biomechanics (Bristol, Avon) · 2004

The time-varying response of the in vivo lumbar spine to dynamic repetitive flexion.

Parkinson Robert J, Beach Tyson A C, Callaghan Jack P

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To quantify the time-varying stiffness and kinematic responses of the in vivo lumbar spine exposed to dynamic repetitive flexion movements.

DESIGN

Changes in in vivo passive lumbar moment-angle relationships were monitored in response to dynamic repetitive flexion.

BACKGROUND

While previous in vitro studies have provided conflicting evidence on the effects of repetitive flexion movements on the stiffness of the lumbar spine, no previous studies have quantified the time-varying changes of the in vivo lumbar spine to dynamic repetitive flexion.

METHODS

Subjects lifted and lowered a 4.5 kg load over two barriers at a rate of 7 lifts per minute for 1.5 h inducing at least 80% of the lumbar flexion range of motion. Prior to lifting and at 30 min intervals passive moment-angle relationships were obtained by pulling the subject into flexion on a customized frictionless table.

RESULTS

Repetitive lifting induced a decreasing stiffness trend after 30 min, followed by a recovery towards initial stiffness levels with further loading. The trends were non-significant for all measures studied.

CONCLUSIONS

The results indicate that after 30 min of lifting, creep within the passive tissues may allow workers to exceed their initial range of motion, altering joint mechanics and loading patterns potentially leading to an increased risk of developing low back pain.

RELEVANCE: Given the potential for time-varying changes to alter the spine's risk of injury and injury mechanisms, knowledge regarding the stiffness response of the in vivo lumbar spine exposed to repetitive flexion may lead to improved understanding and prevention of work related back pain.

Для цитирования: Parkinson Robert J, Beach Tyson A C, Callaghan Jack P. The time-varying response of the in vivo lumbar spine to dynamic repetitive flexion.. Clinical biomechanics (Bristol, Avon). 2004. DOI: 10.1016/j.clinbiomech.2004.01.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.