MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/lam.13130

Медицинская библиотека · Letters in applied microbiology · 2019

Loop-mediated isothermal amplification for paratyphoid fever - a proof-of-principle analysis.

Rojak S, Wiemer D F, Wille A, Loderstädt U, Wassill L, Hinz R, Hagen R M, Frickmann H

СтатьяПеревод в очереди

Аннотация

In-house loop-mediated isothermal amplification (LAMP) procedures for the detection of paratyphoid fever-associated bacteria on serovar level were evaluated. Therefore, LAMP primers for Salmonella genus, for two LAMP schemes for S. Paratyphi A, for S. Paratyphi B and for S. Paratyphi C were tested with DNA from culture isolates from strain collections and spiked blood cultures against published PCR protocols targeting the same micro-organisms. Sensitivity and specificity for DNA from culture isolates verified by LAMP ranged from 80·0 to 100·0% and 96·1 to 100·0% vs 65 to 100% and 98·7 to 100% for the PCR approaches. For the spiked blood culture materials, sensitivity and specificity for LAMP ranged from 87·5 to 100·0% and 96·7 to 100·0% vs from 60 to 100% and 98·2 to 100% for PCR. In conclusion, LAMP for paratyphoid fever shows comparable performance characteristics as PCR. Due to its easy application, the procedure is well suited for surveillance purposes in resource-limited settings. SIGNIFICANCE AND IMPACT OF THE STUDY: The use of easy-to-apply, point-of-care-testing-like loop-mediated isothermal amplification (LAMP) for the diagnosis of paratyphoid fever is evaluated. This approach can contribute to low-threshold availability of surveillance options for resource limited settings. Easy-to-teach and easy-to-apply LAMP schemes with similar performance characteristics as PCR are provided. The described test evaluation is of particular use for surveillance and public health experts.

Для цитирования: Rojak S, Wiemer D F, Wille A, Loderstädt U, Wassill L, Hinz R, Hagen R M, Frickmann H. Loop-mediated isothermal amplification for paratyphoid fever - a proof-of-principle analysis.. Letters in applied microbiology. 2019. DOI: 10.1111/lam.13130.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.