MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jmri.25300

Медицинская библиотека · Journal of magnetic resonance imaging : JMRI · 2016

Application value of diffusion weighted whole body imaging with background body signal suppression in monitoring the response to treatment of bone marrow involvement in lymphoma.

Sun Mengtian, Cheng Jingliang, Zhang Yong, Wang Feifei, Meng Yun, Fu Xiaorui

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To investigate the application value of diffusion weighted whole body imaging with background body signal suppression (DWIBS) in monitoring the response to treatment of bone marrow involvement in lymphoma.

MATERIALS AND

METHODS

Twenty-one lymphoma patients with bone marrow involvement underwent 1.5 Tesla DWIBS before chemotherapy and after the second chemotherapy session (median interval, 8 weeks; range 7-11 weeks). Apparent diffusion coefficient (ADC) values of bone marrow lesions were measured before and after treatment. The difference in ADC values before and after treatment in responders and nonresponders was analyzed.

RESULTS

Seventy-three cases of bone marrow lesions were diagnosed in 21 lymphoma patients before the treatment. After the second chemotherapy session, 18 patients (57 lesions) and 3 patients (9 lesions) were categorized into the responder and nonresponder group, respectively. The mean pretreatment ADC value of all lesions was 0.90 ± 0.39 × 10-3 mm2 /s, of which the mean ADC values of the responder group and nonresponder group were 0.92 ± 0.40 × 10-3 mm2 /s and 0.79 ± 0.29 × 10-3 mm2 /s, respectively (between-group difference: t = -0.94; P = 0.351). The posttreatment ADC value of the responder group significantly increased (66.39% ± 83.11%; P < 0.001) while the posttreatment ADC value of the nonresponder group slightly increased (5.32% ± 17.31%). The difference in the rate of change of ADC values in the responder and nonresponder groups before and after the treatment was significant (P < 0.05).

CONCLUSION

DWIBS in combination with the measurement of ADC values enabled a good short-term response evaluation for bone marrow involvement in lymphoma. However, the pretreatment ADC value indicated no significant predictive value for responses to the treatment. J. Magn. Reson. Imaging 2016;44:1522-1529.

Для цитирования: Sun Mengtian, Cheng Jingliang, Zhang Yong, Wang Feifei, Meng Yun, Fu Xiaorui. Application value of diffusion weighted whole body imaging with background body signal suppression in monitoring the response to treatment of bone marrow involvement in lymphoma.. Journal of magnetic resonance imaging : JMRI. 2016. DOI: 10.1002/jmri.25300.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.