Медицинская библиотека · Practical radiation oncology · 2015

Interobserver variability in clinical target volume delineation for primary mediastinal B-cell lymphoma.

Piva Cristina, Genovesi Domenico, Filippi Andrea Riccardo, Balducci Mario, Barra Salvina, Buglione Michela, Busetto Mario, Ciammella Patrizia, Franzone Paola, De Sanctis Vitaliana, Simontacchi Gabriele, Fusella Marco, Ricardi Umberto, Radiation Oncology Committee of the Italian Lymphoma Foundation (FIL)

Клинический случайСтатьяПеревод в очереди

Аннотация

PURPOSE: The purpose of this study was to evaluate interobserver variability among radiation oncologists with experience in the field of lymphoma radiation therapy in the delineation of clinical target volume (CTV) in a challenging case of primary mediastinal B-cell lymphoma.

METHODS AND MATERIALS: Ten experienced radiation oncologists were invited to a 1-day contouring session. The case of a 56-year-old man with primary mediastinal B-cell lymphoma with complete metabolic response after chemotherapy was chosen as the sample for the study. A brief presentation of his clinical history was given, together with guidelines for contouring. The 10 CTVs obtained were then compared in terms of variation in total volume and in craniocaudal, laterolateral, and anteroposterior diameters. The CTV with the best Dice similarity coefficient (DSC) between the union of all 10 CTVs and the individual CTV was considered the reference CTV, and the DSC and the Hausdorff distance (HD) for each volume compared with the reference CTV were then calculated.

RESULTS

A significant variability was found in total volume (mean, 498.3 cm(3); range, 181.8-1003 cm(3)) and craniocaudal (median, 144.7 mm; range, 80.6-159 mm), laterolateral (median, 133.5 mm; range, 83.7-149.5 mm), and anteroposterior diameters (median, 136.2 mm; range, 84-150.5 mm). Analysis of the DSC and the HD showed a mean DSC of 0.53 (range, 0.31-0.74) and a mean HD of 6.4 cm (range, 1.8-14.8 cm).

CONCLUSIONS

Results of this study strongly indicate the need to develop and share appropriate contouring guidelines among experts and suggest the promotion of specific educational activities to improve radiation therapy quality in both clinical trials and routine clinical practice.

Для цитирования: Piva Cristina, Genovesi Domenico, Filippi Andrea Riccardo, Balducci Mario, Barra Salvina, Buglione Michela, Busetto Mario, Ciammella Patrizia, Franzone Paola, De Sanctis Vitaliana, Simontacchi Gabriele, Fusella Marco, Ricardi Umberto, Radiation Oncology Committee of the Italian Lymphoma Foundation (FIL). Interobserver variability in clinical target volume delineation for primary mediastinal B-cell lymphoma.. Practical radiation oncology. 2015. DOI: 10.1016/j.prro.2015.04.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.