m+Medelevator.RU
← Поиск публикаций
The Science of the total environment · 2019

Using a paired tower approach and remote sensing to assess carbon sequestration and energy distribution in a heterogeneous sclerophyll forest.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Griebel Anne, Metzen Daniel, Boer Matthias M, Barton Craig V M, Renchon Alexandre A, Andrews Holly M, Pendall Elise

Аннотация

The critically endangered Cumberland Plain woodland within the greater Sydney metropolitan area hosts a dwindling refuge for melaleuca trees, an integral part of Australia's native vegetation. Despite their high carbon stocks, melaleucas have not explicitly been targeted for studies assessing their carbon sequestration potential, and especially little is known about their energy cycling or their response to increasing climate stress, precluding a holistic assessment of the resilience of Australia's forests to climate change. To improve our understanding of the role of melaleuca forest responses to climate stress, we combined forest inventory and airborne LiDAR data to identify species distribution and associated variations in forest structure, and deployed flux towers in a melaleuca-dominated (AU-Mel) and in a eucalypt-dominated (AU-Cum) stand to simultaneously monitor carbon and energy fluxes under typical growing conditions, as well as during periods with high atmospheric demand and low soil water content. We discovered that the species distribution at our study site affected the vertical vegetation structure, leading to differences in canopy coverage (75% at AU-Cum vs. 84% at AU-Mel) and plant area index (2.1 m2 m-2 at AU-Cum vs. 2.6 m2 m-2 at AU-Mel) that resulted in a heterogeneous forest landscape. Furthermore, we identified that both stands had comparable net daytime carbon exchange and sensible heat flux, whereas daytime latent heat flux (115.8 W m-2 at AU-Cum vs 119.4 W m-2 at AU-Mel, respectively) was higher at the melaleuca stand, contributing to a 0.3 °C decrease in air temperature and reduced vapor pressure deficit above the melaleuca canopy. However, increased canopy conductance and higher latent heat flux during moderate VPD or when soil moisture was low indicated a lack of water preservation at the melaleuca stand, highlighting the potential for increased vulnerability of melaleucas to projected hotter and drier future climates.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты