MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · JOP : Journal of the pancreas · 2009

Are large side holes associated with reduced rates of pancreatic stent occlusion? Results of a prospective study.

Buscaglia Jonathan M, DiMaio Christopher J, Pollack Michael J, Shin Eun Ji, Harris Michael D, Richards Robert, Chak Amitabh, Kantsevoy Sergey V, Jagannath Sanjay B, Okolo Patrick I

Клиническое исследованиеСтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

CONTEXT: Pancreatic stents are frequently clogged at the time of removal. There is limited data regarding the factors associated with stent occlusion.

OBJECTIVES

To estimate the frequency of stent occlusion at the time of removal, to study the accuracy of endoscopic prediction of occlusion, and to determine the factors associated with clogged pancreatic stents.

SETTING

Consecutive patients at 4 academic medical centers undergoing removal of a previously placed pancreatic stent were prospectively enrolled.

PATIENTS: A total of 68 patients were enrolled between August 2007 and July 2008.

INTERVENTIONS: Following removal, stent occlusion was immediately assessed by complete lack of water flow from the duodenal end and side holes of the stent.

MAIN OUTCOME MEASURE: Survival analysis was performed using a Kaplan-Meier and Cox Regression model.

RESULTS

Indications for stent placement included chronic pancreatitis (n=23), pancreatic duct leak (n=7), prevention of post-ERCP pancreatitis (n=28), pseudocyst drainage (n=1), pancreas divisum (n=8), and pancreatic duct stricture without chronic pancreatitis (n=1). Standard Geenen (Cook Endoscopy, Winston-Salem, NC, USA) pancreatic stents were placed in 53 patients (77.9%). The majority of stents (42, 61.8%) were completely occluded at the time of removal. Median time to stent occlusion was 35 days (95% CI: 30-40 days). Stent type, diameter, length, number of small side holes, and indication for placement were not predictive of subsequent stent occlusion. However, stents with at least 4 large, flange-associated side holes were 54% less likely to be clogged upon removal (HR=0.46, P=0.029).

CONCLUSIONS

Pancreatic stents are mostly occluded as early as 1 month after insertion. Larger side holes may prevent stents within the pancreas from becoming clogged.

Для цитирования: Buscaglia Jonathan M, DiMaio Christopher J, Pollack Michael J, Shin Eun Ji, Harris Michael D, Richards Robert, Chak Amitabh, Kantsevoy Sergey V, Jagannath Sanjay B, Okolo Patrick I. Are large side holes associated with reduced rates of pancreatic stent occlusion? Results of a prospective study.. JOP : Journal of the pancreas. 2009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.