MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/radiology.214.1.r00ja13143

Медицинская библиотека · Radiology · 2000

Percutaneous ethanol injection of large autonomous hyperfunctioning thyroid nodules.

Tarantino L, Giorgio A, Mariniello N, de Stefano G, Perrotta A, Aloisio V, Tamasi S, Forestieri M C, Esposito F, Esposito F, Finizia L, Voza A

СтатьяПеревод в очереди

Аннотация

PURPOSE: To verify the effectiveness of percutaneous ethanol injection (PEI) in the treatment of large (>30-mL) hyperfunctioning thyroid nodules.

MATERIALS AND

METHODS

Twelve patients (eight women, four men; age range, 26-76 years) with a large hyperfunctioning thyroid nodule (volume range, 33-90 mL; mean, 46.08 mL) underwent PEI treatment under ultrasonographic (US) guidance. US was used to calculate the volume of the nodules and to assess the diffusion of the ethanol in the lesions during the procedure. When incomplete necrosis of the nodule was depicted at scintigraphy performed 3 months after treatment, additional PEI sessions were performed.

RESULTS

Four to 11 PEI sessions (mean, seven) were performed in each patient, with an injection of 3-14 mL of 99.8% ethanol per session (total amount of ethanol per patient, 30-108 mL; mean, 48.5 mL). At scintigraphy after treatment in all patients, recovery of extranodular uptake, absence of uptake in the nodule, and normalization of thyroid-stimulating hormone (thyrotropin) levels were observed. In all patients, US showed volume reductions of 30%-50% after 3 months and 40%-80% after 6-9 months. Side effects were self-limiting in all patients. During the 6-48-month follow-up, no recurrence was observed.

CONCLUSION

PEI is an effective and safe technique for the treatment of large hyperfunctioning thyroid nodules.

Для цитирования: Tarantino L, Giorgio A, Mariniello N, de Stefano G, Perrotta A, Aloisio V, Tamasi S, Forestieri M C, Esposito F, Esposito F, Finizia L, Voza A. Percutaneous ethanol injection of large autonomous hyperfunctioning thyroid nodules.. Radiology. 2000. DOI: 10.1148/radiology.214.1.r00ja13143.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.