m+Medelevator.RU
← Поиск публикаций
Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis · 2026

Clinical Evaluation of the Hemostatic Efficacy and Safety of a Biodegradable Hemostatic Agent, Hemogram: A Comparative Study with Arista™ AH.

СтатьяРандомизированное исследованиеСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Min Seung Ki, Oh Sung Eun, An Ji Yeong, Kim Hyun Kyoon, Kim Eun Jin, Choi Min-Gew

Аннотация

BackgroundHemogram is a novel biodegradable powdered hemostatic agent developed by binding calcium ions (Ca²+) to carboxymethyl starch (CM-starch) and applying granulation technology to enhance blood absorption and hemostatic efficacy. This study aimed to evaluate the clinical efficacy and safety of Hemogram compared with the commercially available agent Arista™ AH in patients undergoing gastrectomy.MethodsThis randomized controlled trial was conducted at Samsung Medical Center and included patients who experienced intraoperative oozing-type bleeding during gastrectomy. A total of 64 patients were enrolled and evenly randomized to receive either Hemogram (n = 32) or Arista™ AH (n = 32) for local hemostasis. The primary efficacy endpoint was the hemostatic success rate within 5 min. Secondary endpoints included hemostasis time, re-bleeding rate, number of hemostatic agent units used, transfusion volume, length of hospital stay, and incidence of adverse events.ResultsHemostatic success within 5 min was achieved in 100% (32/32) of the Hemogram group and 96.9% (31/32) of the Arista™ AH group, with no statistically significant difference between the two (P > 0.05). The mean time to hemostasis was 1.25 ± 0.80 min in the Hemogram group and 1.52 ± 0.85 min in the Arista™ AH group. No re-bleeding events were observed in the Hemogram group, while one case of re-bleeding (3.3%) was reported in the Arista™ AH group. There were no significant differences between groups in terms of transfusion volume, length of hospitalization, or adverse event rates.ConclusionHemogram demonstrated non-inferior hemostatic efficacy and safety compared to Arista™ AH in patients undergoing gastrectomy. These findings suggest that Hemogram is a promising and clinically applicable hemostatic agent for surgical use.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты