m+Medelevator.RU
← Поиск публикаций
Talanta · 2025

A simple and low-cost paper chip-based smartphone sensor for enumeration of T lymphocyte subsets.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Xiao Wei, Xu Fengjuan, Lin Cong, Zhao Qian, Han Yuanyuan, Lu Kunjie, Su Yanqiong, Shang Shibo, Deng Jiting, Gong Ke, Fang Xiaolin, Hu Liangshan, Cao Donglin

Аннотация

Lymphocyte count reflects the cellular immune function status of the body, and T lymphocyte subsets are of great value in the adjuvant diagnosis, efficacy monitoring, and prognostic assessment of clinical diseases. There is an urgent need to develop a simple and economical cell-counting platform for T lymphocyte subsets to meet clinical needs of cancer prognosis. Based on the vertical flow assay (VFA) and a polystyrene (PS) microsphere-labeled antibody specifically binding to target cells, we established a simple T lymphocyte counting assay (PS-VFA). Labeled cells induced a signal, which was detected on the filter membrane. We used 3D printing to create a cell phone holder and a test kits. The cell phone holder eliminates ambient light interference and provides the appropriate focus, and a smartphone was used for image acquisition and data analysis, revealing the number of T lymphocytes to be tested via RGB signal analysis. The entire detection process takes about 15 min, and the detection device is extremely cheap, about $20, and can be reused. CD3, CD4, and CD8 cells count exhibited a quasilinear response to logarithmic cell concentrations in a single nucleated cell solution, and detection limits ranging from 100 to 1400 cells/μL for CD3(R2 = 0.96), 100 to 1400 cells/μL for CD4(R2 = 0.97), and 25 to 800 cells/μL for CD8(R2 = 0.96), respectively. And the CV values of this method are all less than 10 %. To validate the clinical applicability of this method,16 patients with cancer and 34 healthy individuals samples were measured, the detection results showed a high correlation with the flow cytometry (FCM) analysis. These results revealed that PS-VFA showed good performance compared with flow cytometry and precision evaluation. This analysis approach is a promising alternative for the costly standard flow cytometry-based tools for T lymphocyte subsets in tumor patients in resource-limited settings.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты