BACKGROUND AND

OBJECTIVES

Wrong blood in tube (WBIT) continues to be a preventable cause of unintended harm to the patient. The literature describing extent of the problem, its consequences and factors leading to WBIT from the perspective of lower middle-income countries (LMICs) is limited. The present study describes WBIT and its outcome in a hospital-based blood centre from an LMIC.

MATERIALS AND

METHODS

WBIT events occurring during the study period were analysed to identify the root cause. In addition, they were analysed according to discipline, department and time of sample draw. Root causes were divided and compared with standard operating procedure (SOP) for sample collection for blood requests. All WBIT events were followed and their outcomes analysed.

RESULTS

WBIT events occurred at a rate of 4.8/10,000 blood requests, with a higher rate in urgent requests (5.2/10,000 requests). The average rate of WBIT was higher in surgical disciplines compared to medical and acute care services (6.58 vs. 4.43 vs. 3/10,000 requests). The highest rate of WBIT was observed when requests were received during 8:00 PM-2:00 AM (p = 0.02). Deviations from SOP with contribution from human and organizational elements were identified as the root cause. The consequences ranged from delay in providing blood to acute haemolytic transfusion reactions.

CONCLUSION

We found that WBITs occurred at a rate comparable to that reported from developed countries. Use of software and automation may reduce the rate of WBIT but not eliminate it completely. Strict adherence to SOPs and continuous training of phlebotomy staff would help reduce it to a minimum. Blood centres need to develop specific strategies with respect to their root causes.

Для цитирования: Krishna Aparna, Pandey Hem Chandra, Coshic Poonam, Kumar Rakesh, Jain Romesh. Analysis of wrong blood in tube events at a hospital-based blood centre in a tertiary care referral hospital: A perspective from a lower middle-income country.. Vox sanguinis. 2024. DOI: 10.1111/vox.13767.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.