Postoperative outcomes and trends in computer-navigated and robotic-assisted total hip arthroplasty.
Аннотация
INTRODUCTION
As the volume of technology-assisted total hip arthroplasty (THA) increases, there is a need to characterise the outcomes of robotic-assisted (RA) and computer-navigated (CN) THA. The goal of this study was to assess outcomes and opioid consumption following CN-THA and RA-THA compared to conventionally-instrumented (CON) THA.
METHODS
The Premier Database was queried for all patients who underwent primary, elective THA from 2015-2020. Patients were divided into 3 groups: CN, RA, or CON-THA. Yearly usage trends were assessed. Univariate and multivariate analyses were performed to assess the 90-day risk of postoperative complications. Opioid consumption was reported in morphine milligram equivalents (MME) for postoperative days (POD) 0 and 1.
RESULTS
Overall, 474,707 elective THAs were identified (95.7% CON, 2.1% CN, 2.2% RA. After accounting for confounders, CN-THA patients were at decreased risk for periprosthetic joint infection (PJI) (aOR: 0.55, p < 0.001) and dislocation (aOR 0.45, p < 0.001), but increased risk for blood transfusion (aOR 1.97, <0.001) compared to CON-THA. RA-THA patients were at decreased risk of dislocation (aOR:0.66, p < 0.001) but increased risk for transfusion (aOR 1.20, p < 0.001), prosthesis breakage (aOR 3.88, p < 0.001), and periprosthetic fracture (aOR 1.72, p < 0.001). Opioid consumption for CN-THA patients was lower on POD1 and lower for RA-THA patients POD0 and 2 compared to CON-THA.
DISCUSSION: CN-THA was associated with reduced rates of PJI and dislocation, but increased rates of blood transfusion while RA-THA was associated with decreased rates of dislocation, but increased rates of blood transfusion, prosthesis complications, and periprosthetic fracture compared to CON-THA. Technology-assisted THA was associated with lower postoperative opioid consumption.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.