MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s13730-024-00912-z

Медицинская библиотека · CEN case reports · 2024

A case of hyperviscosity syndrome associated with Waldenström macroglobulinemia treated with membrane plasma exchange without predilution.

Saiki Koichi, Sofue Tadashi, Higashiyama Chikako, Shiga Takafumi, Aoki Yuhei, Shiraishi Aiko, Kunisho Yasushi, Onishi Keisuke, Nakamura Eisuke, Ishida Tomoya, Minamino Tetsuo

Клинический случайСтатьяПеревод в очереди

Аннотация

A 75-year-old man with blurred vision and nasal bleeding was diagnosed with hyperviscosity syndrome and central retinal vein occlusion secondary to Waldenström macroglobulinemia. Serum total protein and IgM levels were undetectable. Because of the severe symptoms, we determined that immediate plasma-exchange treatment was required to decrease the blood viscosity. The initial plasma exchange was performed using the membrane isolation method with a predilution standby. A saline predilution replacement was prepared to decrease the total membrane pressure (TMP); however, the predilution protocol was not used because the planned treatment volume could be achieved without increasing the TMP. After two consecutive days of membrane plasma exchange, all serum biochemical tests were measurable, and IgM was below 4000 mg/dL. After chemotherapy, his visual symptoms improved, and he was discharged. Since it is difficult to assess the risk of elevated TMP prior to initial plasma exchange, membrane plasma exchange with a predilution standby may be a useful strategy for initial plasma exchange for hyperviscosity syndrome in terms of safety and efficiency.

Для цитирования: Saiki Koichi, Sofue Tadashi, Higashiyama Chikako, Shiga Takafumi, Aoki Yuhei, Shiraishi Aiko, Kunisho Yasushi, Onishi Keisuke, Nakamura Eisuke, Ishida Tomoya, Minamino Tetsuo. A case of hyperviscosity syndrome associated with Waldenström macroglobulinemia treated with membrane plasma exchange without predilution.. CEN case reports. 2024. DOI: 10.1007/s13730-024-00912-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.