MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jca.22110

Медицинская библиотека · Journal of clinical apheresis · 2024

Assessing the clinical efficacy of low-volume therapeutic plasma exchange in achieving recovery from acute liver failure induced by yellow phosphorous poisoning.

Ninan Ancy, Mohan Ganesh, Shanbhag Vishal, Chenna Deepika, Shastry Shamee, Rao Shwethapriya

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Acute liver failure (ALF) following yellow phosphorous (YP) ingestion is similar to acetaminophen-induced ALF and it has become a public concern in our region. This study assessed low volume therapeutic plasma exchange (LV-TPE) efficacy in improving the transplant free survival in YP poisoning.

METHODS

Adult patients with toxicology reports of YP and ALF requiring critical care were included in the study. LV-TPE was planned for three consecutive days and three more if required. Performed 1.3 to 1.5 plasma volume replacing with 0.9% normal saline, 5% human albumin solution, and fresh frozen plasma based on ASFA 2019 criteria. MELD score, laboratory parameters, LV-TPE details were captured. The study end point was clinical outcome of the patients.

RESULTS

Among 36 patients, 19 underwent LV-TPE and 17 opted out of LV-TPE and they were included as a control arm. The MELD score was 32.64 ± 8.05 and 37.83 ± 9.37 in both groups. There were 13 survivors in LV-TPE group leading to a 68.42% reduction in mortality. The coagulation and biochemical parameters showed a significant percentage change after LV-TPE. Refractory shock, delay in initiating procedure and acidosis were independent predictors of mortality.

CONCLUSION

A well-timed LV-TPE improves the survival of patients with ALF due to YP poisoning.

Для цитирования: Ninan Ancy, Mohan Ganesh, Shanbhag Vishal, Chenna Deepika, Shastry Shamee, Rao Shwethapriya. Assessing the clinical efficacy of low-volume therapeutic plasma exchange in achieving recovery from acute liver failure induced by yellow phosphorous poisoning.. Journal of clinical apheresis. 2024. DOI: 10.1002/jca.22110.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.