OBJECTIVE

To describe long-term outcomes of the Ross procedure in a single center and retrospective series after 25 years follow-up.

METHODS

From 1997-2019 we included all consecutive patients who underwent Ross procedure at our center. Clinical and echocardiographic evaluations were performed at least yearly. Echocardiographic valvular impairment was defined as at least moderate autograft or homograft dysfunction. Reintervention outcomes included surgical and percutaneous approach.

RESULTS

151 Ross procedures were performed (mean age 28±12years, 21 %<16years, 70 %male). After 25 years follow-up (median 18 years, interquartile range 9-21, only 3 patients lost) 12 patients died (8 %); Autograft, homograft or any valve dysfunction were present in 38(26 %), 48(32 %) and 75(51 %), respectively; and reintervention in 22(15%), 17(11%) and 38(26 %) respectively. At 20 years of follow-up, probabilities of survival free from autograft, homograft or any valve dysfunction were 63 %, 60 % and 35 %; and from reintervention, 80 %, 85 % and 67 %, respectively. The learning curve period (first 12 cases) was independently associated to autograft dysfunction (HR 2.78, 95 %CI:1.18-6.53, p = 0.02) and reintervention (HR 3.76, 95 %CI: 1.46-9.70, p = 0.006). Larger native pulmonary diameter was also an independent predictor of autograft reintervention (HR 1.22, 95 %CI:1.03-1.45, p = 0.03). Homograft dysfunction was associated with younger age (HR 5.35, 95 %CI: 2.13-13.47, p<0.001) and homograft reintervention, with higher left ventricle ejection fraction (HR 1,10, 95 %CI:1.02-1.19, p<0.02).

CONCLUSIONS

In this 25 years' experience after the Ross procedure, global survival was high, although autograft and homograft dysfunction and reintervention rates were not negligible. Clinical and echocardiographic variables can identify patients with higher risk of events in follow up.

Для цитирования: Pardo González Laura, Ruiz-Ortiz Martín, Delgado Mónica, Rodriguez Sara, Villalba Rafael, Merino Carlos, Casares Jaime, Mesa Dolores, Suárez de Lezo José, Pan Manuel. Ross procedure: valve function, clinical outcomes and predictors after 25 years' follow-up.. Current problems in cardiology. 2024. DOI: 10.1016/j.cpcardiol.2024.102410.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.