m+Medelevator.RU
← Поиск публикаций
Journal of pharmaceutical and biomedical analysis · 2023

A fully validated method for simultaneous determination of icotinib, osimertinib, gefitinib and O-desmethyl gefitinib in human plasma using UPLC-MS/MS for therapeutic drug monitoring.

СтатьяВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Li Bo, Chen Wenqian, Liu Fang, Wang Xiaoxue, Qin Wei, Li Shu, Lu Hongkai, Wang Guan, Liu Xiaoyang, Li Pengmei, Zuo Xianbo, Zhang Xianglin, Liu Lihong, Yang Meng

Аннотация

BACKGROUND AND AIMS: A few researches have reported the exposure-efficacy/toxicity relationships of epidermal growth factor receptor-tyrosine kinase inhibitors (EGFR-TKIs). On account of the large interpatient pharmacokinetic variability, therapeutic drug monitoring (TDM) seems promising for optimizing dosage regimen and improving treatment efficacy and safety. Therefore, a rapid and convenient ultrahigh performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the determination of icotinib, osimertinib, gefitinib and O-demesthyl gefitinib in human plasma for TDM.

MATERIALS AND METHODS: Icotinib-D4 and osimertinib-13CD3 were used as the internal standards (ISs). The samples were prepared by protein precipitation using acetonitrile. Chromatographic separation was achieved on a 40 ℃ Shimadzu Shim-pack Scepter C18-120 column (2.1 ×50 mm, 3.0 µm, Japan) by a Shimadzu 30 A solvent management system. Detection was carried out using a Shimadzu LC-MS 8050CL triple quadrupole mass spectrometer coupled with an electrospray ionization source in positive mode.

RESULTS: This analytical method was fully validated with selectivity, carry-over, linearity, lower limit of quantification, accuracy (from 92.68% to 106.62%) and precision (intra- and inter-day coefficients of variation ranged from 0.92% to 9.85%), matrix effect, extraction recovery, stability and dilution integrity. The calibration curves were developed to be within the concentration ranges of 200-4000 ng/mL for icotinib, 50-1000 ng/mL for osimertinib, gefitinib and O-desmethyl gefitinib in human plasma which meet the needs of routine TDM.

CONCLUSIONS: The proposed method was used in 100 patients with non-small cell lung cancer for monitoring plasma concentration of the mentioned EGFR-TKIs. The trough concentrations of ICO were distributed between 226.42 ng/mL and 3853.36 ng/mL, peak concentrations were between 609.20 ng/mL and 2191.54 ng/mL. The trough concentrations of OSI were distributed between 110.48 ng/mL and 1183.13 ng/mL. The trough concentrations of GEF were distributed between 117.71 ng/mL and 582.74 ng/mL, while DeGEF was distributed from 76.21 ng/mL to 1939.83 ng/mL with two less than 20 ng/mL. The results of therapeutic drug monitoring aimed to investigate exposure-efficacy/toxicity relationship and improve the efficacy and safety of targeted therapies.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты