MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/trf.17172

Медицинская библиотека · Transfusion · 2022

Silvernanoparticle-induced hemolysis confounded with direct antiglobulin test-negative autoimmune hemolytic anemias diagnosis.

Ringel Frauke, Kiesewetter Holger, Mayer Beate, Bartolmäs Thilo, Sehouli Jalid, Salama Abdulgabar

Клинический случайПоддержка исследования: вне правительства СШАСтатьяПеревод в очереди

Аннотация

BACKGROUND

We describe here the first patient with recurrent hemolysis related to disinfectant containing silver nanoparticles (AgNps).

METHODS

A 58-year-old chemist repeatedly experienced DAT-negative (Coombs-negative) hemolysis during the last 5 years. He was treated with a number of immunosuppressive drugs including 18 times rituximab. The attempt to treat him with cyclosporine A served only to increase the rate of hemolysis. Only by chance, we revealed that the patient regularly used a hand disinfectant containing AgNps. Serological testing was performed using standard techniques. Eryptosis was measured by binding annexin to exposed phosphatidylserine (PS) of the circulating red blood cells (RBCs).

RESULTS

Antiglobulin tests remained negative, and PS exposing RBCs were detected two times during the last hemolytic episodes. Hemolysis completely disappeared following discontinuation of AgNp containing products.

CONCLUSION

AgNps are increasingly being used in a large variety of products. Recently, it was reported that they induce in vitro prohemolytic and procoagulant effects via oxidative stress and eryptosis. The clinical findings imply the hemolysis was provoked by the patient's regular use of cleansing products containing AgNps. Our finding might help to explain the etiology of hemolytical disorders that may remain obscure in many cases.

Для цитирования: Ringel Frauke, Kiesewetter Holger, Mayer Beate, Bartolmäs Thilo, Sehouli Jalid, Salama Abdulgabar. Silvernanoparticle-induced hemolysis confounded with direct antiglobulin test-negative autoimmune hemolytic anemias diagnosis.. Transfusion. 2022. DOI: 10.1111/trf.17172.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.