Robot-Assisted Radical Prostatectomy Using the KangDuo Surgical Robot-01 System: A Prospective, Single-Center, Single-Arm Clinical Study.

Fan Shubo, Zhang Zhongyuan, Wang Jie, Xiong Shengwei, Dai Xiaofei, Chen Xu, Li Zhihua, Han Guanpeng, Zhu Jun, Hao Han, Yu Wei, Cui Liang, Shen Cheng, Li Xuesong, Zhou Liqun

Clinical StudyСтатьяПеревод в очереди

Аннотация

PURPOSE: Our goal was to evaluate the feasibility, safety and effectiveness of the KangDuo Surgical Robot-01 (KD-SR-01) system for robot-assisted radical prostatectomy (RARP).

MATERIALS AND

METHODS

This prospective, single-center, single-arm clinical study was conducted from May 2021 to August 2021. Sixteen RARP procedures with the KD-SR-01 system were performed by 1 surgeon. The perioperative and followup data were prospectively recorded. Early oncologic outcomes were assessed according to surgical margin status and continence was defined as no more than 1 pad daily or urine leakage of ≤20 gm by the 24-hour pad weight test. Ergonomics were assessed with the NASA-TLX (National Aeronautics and Space Administration Task Load Index).

RESULTS

All cases were completed successfully without conversion to traditional RARP, laparoscopic surgery or open surgery. The median docking time, console time and urethrovesical anastomosis time were 5.9 (range, 2.5-11.5), 87 (range, 70-120) and 14.4 minutes (range, 12.0-25.7), respectively. The median estimated blood loss was 50 ml (range, 10-200). None of patients required intraoperative transfusion. The median postoperative hospital stay was 5 days (range, 4-10). Overall, a positive surgical margin occurred in 4 (25%) patients. No biochemical recurrence occurred within 1 month after surgery. The continence rate was 87.5% (14/16) at 1 month after catheter removal. No severe intraoperative or postoperative complications (Clavien-Dindo grade ≥3) occurred. The surgeon reported a high comfort level with a NASA-TLX global score of 22.7±3.2.

CONCLUSIONS

The KD-SR-01 system is feasible, safe and effective for management of localized prostate cancer.

Для цитирования: Fan Shubo, Zhang Zhongyuan, Wang Jie, Xiong Shengwei, Dai Xiaofei, Chen Xu, Li Zhihua, Han Guanpeng, Zhu Jun, Hao Han, Yu Wei, Cui Liang, Shen Cheng, Li Xuesong, Zhou Liqun. Robot-Assisted Radical Prostatectomy Using the KangDuo Surgical Robot-01 System: A Prospective, Single-Center, Single-Arm Clinical Study.. The Journal of urology. 2022. DOI: 10.1097/ju.0000000000002498.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.