m+Medelevator.RU
← Поиск публикаций
Transfusion · 2022

Antibodies against biotin-labeled red blood cells can shorten posttransfusion survival.

СтатьяПоддержка правительства СШАПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mock Donald M, Stowell Sean R, Franco Robert S, Kyosseva Svetlana V, Nalbant Demet, Schmidt Robert L, Cress Gretchen A, Strauss Ronald G, Cancelas José A, von Goetz Melissa, North Anne K, Widness John A

Аннотация

BACKGROUND: In hematologic and transfusion medicine research, measurement of red blood cell (RBC) in vivo kinetics must be safe and accurate. Recent reports indicate use of biotin-labeled RBC (BioRBC) to determine red cell survival (RCS) offers substantial advantages over 51 Cr and other labeling methods. Occasional induction of BioRBC antibodies has been reported.

STUDY DESIGN AND METHODS: To investigate the causes and consequences of BioRBC immunization, we reexposed three previously immunized adults to BioRBC and evaluated the safety, antibody emergence, and RCS of BioRBC.

RESULTS: BioRBC re-exposure caused an anamnestic increase of plasma BioRBC antibodies at 5-7 days; all were subclass IgG1 and neutralized by biotinylated albumin, thus indicating structural specificity for the biotin epitope. Concurrently, specific antibody binding to BioRBC was observed in each subject. As biotin label density increased, the proportion of BioRBC that bound increased antibody also increased; the latter was associated with proportional accelerated removal of BioRBC labeled at density 6 μg/mL. In contrast, only one of three subjects exhibited accelerated removal of BioRBC density 2 μg/mL. No adverse clinical or laboratory events were observed. Among three control subjects who did not develop BioRBC antibodies following initial BioRBC exposure, re-exposure induced neither antibody emergence nor accelerated BioRBC removal.

DISCUSSION: We conclude re-exposure of immunized subjects to BioRBC can induce anamnestic antibody response that can cause an underestimation of RCS. To minimize chances of antibody induction and underestimation of RCS, we recommend an initial BioRBC exposure volume of ≤10 mL and label densities of ≤18 μg/mL.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты