MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2021.113866

Медицинская библиотека · Biosensors & bioelectronics · 2021

Graphene-based hybrid electrical-electrochemical point-of-care device for serologic COVID-19 diagnosis.

Mattioli Isabela A, Castro Karla R, Macedo Lucyano J A, Sedenho Graziela C, Oliveira Mona N, Todeschini Iris, Vitale Phelipe M, Ferreira Suzete Cleusa, Manuli Erika R, Pereira Geovana M, Sabino Ester C, Crespilho Frank N

СтатьяПеревод в очереди

Аннотация

The outbreak of COVID-19 pandemics highlighted the need of sensitive, selective, and easy-to-handle biosensing devices. In the contemporary scenario, point-of-care devices for mass testing and infection mapping within a population have proven themselves as of primordial importance. Here, we introduce a graphene-based Electrical-Electrochemical Vertical Device (EEVD) point-of-care biosensor, strategically engineered for serologic COVID-19 diagnosis. EEVD uses serologic IgG quantifications on SARS-CoV-2 Receptor Binding Domain (RBD) bioconjugate immobilized onto device surface. EEVD combines graphene basal plane with high charge carrier mobility, high conductivity, low intrinsic resistance, and interfacial sensitivity to capacitance alterations. EEVD application was carried out in real human serum samples. Since EEVD is a miniaturized device, it requires just 40 μL of sample for a point-of-care COVID-19 infections detection. When compared to serologic assays such ELISA and other immunochromatographic methods, EEVD presents some advantages such as time of analyses (15 min), sample preparation, and a LOD of 1.0 pg mL-1. We glimpse that EEVD meets the principles of robustness and accuracy, desirable analytic parameters for assays destined to pandemics control strategies.

Для цитирования: Mattioli Isabela A, Castro Karla R, Macedo Lucyano J A, Sedenho Graziela C, Oliveira Mona N, Todeschini Iris, Vitale Phelipe M, Ferreira Suzete Cleusa, Manuli Erika R, Pereira Geovana M, Sabino Ester C, Crespilho Frank N. Graphene-based hybrid electrical-electrochemical point-of-care device for serologic COVID-19 diagnosis.. Biosensors & bioelectronics. 2021. DOI: 10.1016/j.bios.2021.113866.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.