DOI 10.1016/j.transproceed.2021.07.018
Perioperative Viscoelastic Assay Use for Monitoring Coagulation Among US Liver Transplantation Centers.
Аннотация
BACKGROUND
Viscoelastic assay has been used in liver transplantation since 1985 and shown to be beneficial in detecting coagulopathy and to guide transfusion. The objective of this study was to review and evaluate the current uses of viscoelastic assay among US liver transplantation programs.
METHODS
Anesthesia program directors at all 137 liver transplantation centers in the United States were contacted via email and asked to complete a 21-item survey. The primary outcome measure was the percentage of viscoelastic assay used in the perioperative management of liver transplantation. Secondary outcome measures were institutional demographics, physician training level, and device demographics.
RESULTS
Sixty-one of 137 (46%) centers responded. Liver transplantations were performed in the university setting at 48 of the 61 centers (77%), with a modal value of 11 to 50 liver transplantations a year and 74% in adult patients only. Most of the institutions (n = 57, 92%) had access to either rotational thromboelastometry or thrombelastography during liver transplantation. Most centers (n = 54; 87%) also used viscoelastic monitoring routinely (>60% of the time), including 42 (67.7%) that always used viscoelastic assay intraoperatively during liver transplantation. Thirty-five centers (59%) used it preoperatively, and 51 (84%) used it postoperatively. Most viscoelastic assay users (68%) learned how to use it through self-education and 10.5% learned during their fellowship or from a superuser or colleagues.
CONCLUSION
Currently, viscoelastic monitoring is widely available and routinely used in most US liver transplantation centers regardless of university or private practice setting, but training in it is limited. Only 21.1% of respondents reported that they received any type of official training in viscoelastic assay interpretation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.