MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00404-021-06055-1

Медицинская библиотека · Archives of gynecology and obstetrics · 2021

Diagnostic performance of the noninvasive prenatal FetoGnost RhD assay for the prediction of the fetal RhD blood group status.

Legler Tobias J, Lührig Sandra, Korschineck Irina, Schwartz Dieter

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To evaluate the diagnostic accuracy of a commercially available test kit for noninvasive prenatal determination of the fetal RhD status (NIPT-RhD) with a focus on early gestation and multiple pregnancies.

METHODS

The FetoGnost RhD assay (Ingenetix, Vienna, Austria) is routinely applied for clinical decision making either in woman with anti-D alloimmunization or to target the application of routine antenatal anti-D prophylaxis (RAADP) to women with a RhD positive fetus. Based on existing data in the laboratory information system the newborn's serological RhD status was compared with NIPT RhD results.

RESULTS

Since 2009 NIPT RhD was performed in 2968 pregnant women between weeks 5 + 6 and 40 + 0 of gestation (median 12 + 6) and conclusive results were obtained in 2888 (97.30%) cases. Diagnostic accuracy was calculated from those 2244 (77.70%) cases with the newborn's serological RhD status reported. The sensitivity of the FetoGnost RhD assay was 99.93% (95% CI 99.61-99.99%) and the specificity was 99.61% (95% CI 98.86-99.87%). No false-positive or false-negative NIPT RhD result was observed in 203 multiple pregnancies.

CONCLUSION

NIPT RhD results are reliable when obtained with FetoGnost RhD assay. Targeted routine anti-D-prophylaxis can start as early as 11 + 0 weeks of gestation in singleton and multiple pregnancies.

Для цитирования: Legler Tobias J, Lührig Sandra, Korschineck Irina, Schwartz Dieter. Diagnostic performance of the noninvasive prenatal FetoGnost RhD assay for the prediction of the fetal RhD blood group status.. Archives of gynecology and obstetrics. 2021. DOI: 10.1007/s00404-021-06055-1.