m+Medelevator.RU
← Поиск публикаций
Transfusion · 2021

Personalized collection of plasma from healthy donors: A randomized controlled trial of a novel technology-enabled nomogram.

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hartmann Jan, Ragusa Michael J, Burchardt Elmar R, Manukyan Zorayr, Popovsky Mark A, Leitman Susan F

Аннотация

BACKGROUND: Source plasma is essential to support the growing demand for plasma-derived medicinal products. Supply is short, with donor availability further limited by the coronavirus disease 2019 (COVID-19) pandemic. This study examined whether a novel, personalized, technology-based nomogram was noninferior with regard to significant hypotensive adverse events (AEs) in healthy donors.

STUDY DESIGN AND METHODS: IMPACT (IMproving PlasmA CollecTion) was a prospective, multicenter, double-blinded, randomized, controlled trial carried out between January 6 and March 26, 2020, in three U.S plasma collection centers. Donors were randomly assigned to the current simplified 1992 nomogram (control) or a novel percent plasma nomogram (PPN) with personalized target volume calculation (experimental). Primary endpoint was the rate of significant hypotensive AEs. Noninferiority (NI) was tested with a margin of 0.15%. Collected plasma volume was a secondary endpoint.

RESULTS: A total of 3443 donors (mean [SD] BMI: 32 [7.74] kg/m2 ; 65% male) underwent 23,137 donations (median [range]: 6 [1-22] per subject). Ten significant hypotensive AEs were observed (six control; four experimental), with model-based AE incidence rate estimates (95% CI) of 0.051% (0.020%-0.114%) and 0.035% (0.010%-0.094%), respectively (p = .58). NI was met at an upper limit of 0.043% versus the predefined margin of 0.15%. There was no statistical difference between total AEs (all AE types: p = .32). Mean plasma volume collected was 777.8 ml (control) versus 841.7 ml (experimental); an increase of 63.9 ml per donation (8.2%; p < .0001).

CONCLUSION: This trial showed that a novel personalized nomogram approach in healthy donors allowed approximately 8% more plasma per donation to be collected without impairing donor safety.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты