MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/trf.16335

Медицинская библиотека · Transfusion · 2021

Survey of newborn direct antiglobulin testing practice in United States and Canadian transfusion services.

Crowe Elizabeth P, Goel Ruchika, Andrews Jennifer, Meyer Erin K, Wong Trisha E, Sloan Steven R, Delaney Meghan, Lieberman Lani, Cushing Melissa M

СтатьяПеревод в очереди

Аннотация

BACKGROUND

We hypothesized that variability in practice exists for newborn immunohematology testing due to lack of consensus guidelines. We report the results of a survey assessing that variability at hospitals in the United States and Canada.

STUDY DESIGN AND

METHODS

An AABB Pediatric Subsection working party developed and validated a survey of newborn immunohematology testing practice. The survey was sent electronically to transfusion service leadership at teaching institutions.

RESULTS

The response rate was 67% (61/91); 56 surveys meeting inclusion criteria were analyzed. Approximately 90% (50/56) were from birth hospitals and 16.1% (9/56) were from pediatric hospitals. Newborn immunohematology testing is ordered as a panel by 66.0% (33/50) of birth hospitals. ABO group and DAT is mandated before discharge in 14/56 (25.0%) and 13/56 (23.2%), respectively. About 76.8% (43/56) selectively perform a DAT according to blood blank or clinical parameters. The most common DAT practices include anti-IgG only testing by 73.2% (41/56) and use of umbilical cord specimen type by 67.9% (38/56). A positive DAT is a critical value for 26.8% (15/56) and followed with eluate testing when a maternal antibody screen is positive for 48.2% (27/56). In the setting of a non-ABO maternal red cell antibody, 55.4% (31/56), phenotype neonatal red cells when the DAT is positive. Group O RBC are transfused irrespective of the DAT result for 82.1%, (46/56).

CONCLUSION

There is variability in newborn immunohematology testing and transfusion practice and potential overutilization of the DAT. Evidence-based consensus guidelines should be developed to standardize practice and to improve safety.

Для цитирования: Crowe Elizabeth P, Goel Ruchika, Andrews Jennifer, Meyer Erin K, Wong Trisha E, Sloan Steven R, Delaney Meghan, Lieberman Lani, Cushing Melissa M. Survey of newborn direct antiglobulin testing practice in United States and Canadian transfusion services.. Transfusion. 2021. DOI: 10.1111/trf.16335.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.