MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2020.09.018

Медицинская библиотека · JACC. Cardiovascular interventions · 2020

Transcatheter Versus Rapid-Deployment Aortic Valve Replacement: A Propensity-Matched Analysis From the German Aortic Valve Registry.

Abdel-Wahab Mohamed, Fujita Buntaro, Frerker Christian, Bauer Timm, Beckmann Andreas, Bekeredjian Raffi, Bleiziffer Sabine, Möllmann Helge, Walther Thomas, Hamm Christian, Beyersdorf Friedhelm, Zeiher Andreas, Gummert Jan, Herrmann Eva, Borger Michael A, Holzhey David, Thiele Holger, Ensminger Stephan, GARY Executive Board

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

This study sought to compare patient characteristics, procedural outcomes, and valve hemodynamics of surgical aortic valve replacement (SAVR) with current-generation rapid-deployment valves (RDVs) versus transcatheter aortic valve replacement (TAVR) with current-generation transcatheter heart valves (THVs).

BACKGROUND

The patient population currently treated with RDVs may have potential similarities with the current TAVR population, but comparative studies in a large patient population remain scarce.

METHODS

A total of 16,473 patients who underwent isolated SAVR using current-generation RDVs or isolated transfemoral TAVR with current-generation THVs between 2011 and 2017 were enrolled into the German Aortic Valve Registry. Baseline, procedural, and in-hospital outcome parameters were analyzed for RDVs and THVs before and after 1:1 propensity score matching. Furthermore, RDVs and THVs with similar design characteristics were compared with each other.

RESULTS

A total of 1,743 patients received SAVR with an RDV, whereas 14,730 patients were treated with transfemoral TAVR. Patients treated with TAVR were significantly older and had higher surgical risk scores. Following valve replacement, patients treated with an RDV had a significantly higher rate of disabling stroke (1.7% vs. 1.1%; p = 0.03), need for transfusion of >4 red blood cell units (8.5% vs. 1.4%; p < 0.001), and new onset renal replacement therapy (1.9% vs. 1.2%; p = 0.01), whereas the need for a new permanent pacemaker was lower (8.4% vs. 14.9%; p < 0.001). In-hospital mortality was similar (1.6% vs. 1.8%; p = 0.62). These findings persisted after 1:1 propensity score matching, but in-hospital mortality was significantly higher after RDVs (1.7% vs. 0.6%; p = 0.003). Balloon-expandable (BE) RDVs had significantly lower residual gradients compared with BE-THVs, while self-expanding (SE)-RDVs had significantly higher residual gradients compared with SE-THVs.

CONCLUSIONS

In a large all-comers' registry, TAVR with current-generation THVs was associated with improved in-hospital outcomes compared with SAVR with current-generation RDVs. The pacemaker rate is significantly higher with TAVR. Post-procedural hemodynamic function varied between individual RDVs and THVs.

Для цитирования: Abdel-Wahab Mohamed, Fujita Buntaro, Frerker Christian, Bauer Timm, Beckmann Andreas, Bekeredjian Raffi, Bleiziffer Sabine, Möllmann Helge, Walther Thomas, Hamm Christian, Beyersdorf Friedhelm, Zeiher Andreas, Gummert Jan, Herrmann Eva, Borger Michael A, Holzhey David, Thiele Holger, Ensminger Stephan, GARY Executive Board. Transcatheter Versus Rapid-Deployment Aortic Valve Replacement: A Propensity-Matched Analysis From the German Aortic Valve Registry.. JACC. Cardiovascular interventions. 2020. DOI: 10.1016/j.jcin.2020.09.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.