MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/trf.15931

Медицинская библиотека · Transfusion · 2020

Early recognition of possible transfusion reactions using an electronic automatic notification system for changes in vital signs in patients undergoing blood transfusions.

Lim Young Ae, Kim Jin, Park Chorong

Клиническое исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

The study was designed to evaluate the ability of a novel electronic automatic notification system (EANS) to detect significant changes in transfusion-associated vital signs (VSs) during transfusion and to determine whether the EANS improved acute transfusion reaction (ATR) detection rates and suspected ATR reporting rates.

STUDY DESIGN AND

METHODS

VSs were measured three times per unit or batch product transfused:-before, 15 minutes after commencement, and at the completion of the transfusion-and recorded on the EANS. Significant changes in VSs were defined as increased temperature (≥38°C or ≥1°C change in baseline temperature), 20 mm Hg or 20% increase or decrease in systolic blood pressure, or 20% increase in pulse rate. The 6-month periods preceding and after the introduction of the EANS were defined as "before" and "after." Data from these periods were used for comparison and evaluation.

RESULTS

During the after period, 945 notifications were reported from the EANS and 521 suspected ATR were detected. The suspected ATR reporting rates for the before and after were 0.29% (73/25 213) and 2.06% (521/25 304, P < .001) and the ATR detection rates before and after were 0.13% (33/25 213) and 0.49% (116/25 304, P < .001), respectively. Among 116 ATR cases, 49.1% could be detected only by significant changes in VSs.

CONCLUSION

The EANS was very effective in detecting ATRs that could have been overlooked by medical staff. Further data are needed to demonstrate the extent to which the introduction of an EANS may improve the safety of transfused patients.

Для цитирования: Lim Young Ae, Kim Jin, Park Chorong. Early recognition of possible transfusion reactions using an electronic automatic notification system for changes in vital signs in patients undergoing blood transfusions.. Transfusion. 2020. DOI: 10.1111/trf.15931.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.