MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.29095

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2020

Access site related vascular complications with third generation transcatheter heart valve systems.

Ruge Hendrik, Burri Melchior, Erlebach Magdalena, Lange Ruediger

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

This study examines the impact of anatomical and procedural factors on Valve Academic Research Consortium-2-defined vascular complications at the femoral access site in transcatheter aortic valve replacement (TAVR) with third generation transcatheter heart valve (THV)-systems.

BACKGROUND

Randomized clinical trials reported on vascular complications with current THV-systems. However, clinical presentation and consequences of these events are not well studied.

METHODS

All patients who underwent a transfemoral TAVR using an Edwards Sapien3®/Sapien3ultra® or a Medtronic Evolut-R®/Evolut-PRO® have been identified from our institutional database. Only procedures utilizing the PerClose-ProGlide® vascular closure device were included. Risk factors for vascular complications were analyzed with a logistic regression model. Preoperative and procedural data were collected. The postoperative course of patients with and without vascular complications was compared.

RESULTS

A total of 878 patients met the inclusion criteria. Of these, 152 patients (17.3%) had an access-site related vascular complication (87 major complications, 9.9%). Sheath-to-femoral-artery-ratio (SFAR) (OR per 0.1 increase = 1.35, p < .001) and more than 2 vessel entries with large bore sheaths (OR = 1.76, p = .029) were independent risk factors for vascular complications. Female gender (OR = 1.44, p = .07) and two vessel entries with large bore sheaths (OR = 1.2, p = .53) increased the risk, although no statistical significance was shown. Age (OR = 1.07, p = .62), body mass index (OR = 1.1 per 5 points, p = .32) and vessel wall calcification at puncture site (OR = 0.93, p = .7) had no influence on vascular complications. Patients with vascular complications had a higher need for blood transfusion (p < .001) and a higher in-hospital mortality (2.6 vs. 0.4%, p = .019).

CONCLUSIONS

Procedural risk assessment should include SFAR calculation and consider the need for large bore sheath exchange. This might reduce the vascular trauma, lower vascular complication rates and improve the clinical outcome after TAVR.

Для цитирования: Ruge Hendrik, Burri Melchior, Erlebach Magdalena, Lange Ruediger. Access site related vascular complications with third generation transcatheter heart valve systems.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2020. DOI: 10.1002/ccd.29095.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.