MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.transci.2020.102762

Медицинская библиотека · Transfusion and apheresis science : official journal of the World Apheresis Association : official journal of the European Society for Haemapheresis · 2020

Rare case of Auto immune haemolytic anaemia in an infant with auto "f & kidd antibodies".

Gupta Anubhav, Pokhrel Anupa, Sachdeva Prerna, Varshney Shilpi, Arora Harkiran, Chaudhary Kiran, Asati Swati

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

"f" antigen is a compound antigen in Rh blood group system. Anti f has haemolytic potential as described in literature. Its occurrence in an infant as autoantibody with another blood group system ie Jka is very rare. Case report We report a case of 10-month-old infant diagnosed with AIHA with autoantibodies directed towards "f" and Jka antigen. Antibody identification was done and antigen negative blood units were crossmatched & transfused with demonstrable haemoglobin rise and subsequent decrease in DAT grading.

RESULT: Auto anti f + Jka was identified in a 10 months old infant. Autoantibodies were identified by identification 3 & 11 cell panel and select cell panel. Results were later confirmed by allogenic adsorption & elution. Patient was transfused antigen negative blood unit which lead to haemoglobin rise & gradual decrease in direct coombs test grading

CONCLUSION

To our knowledge, this is the first case report of auto anti f + Jka having haemolytic potential in an infant which shows the importance of extensive immmunohaematology workup in providing compatible blood unit in patients with autoantibody.

Для цитирования: Gupta Anubhav, Pokhrel Anupa, Sachdeva Prerna, Varshney Shilpi, Arora Harkiran, Chaudhary Kiran, Asati Swati. Rare case of Auto immune haemolytic anaemia in an infant with auto "f & kidd antibodies".. Transfusion and apheresis science : official journal of the World Apheresis Association : official journal of the European Society for Haemapheresis. 2020. DOI: 10.1016/j.transci.2020.102762.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.