BACKGROUND AND

OBJECTIVES

Fetal RHD genotyping of cell-free maternal plasma DNA from RhD negative pregnant women can be used to guide targeted antenatal and postnatal anti-D prophylaxis for the prevention of RhD immunization. To assure the quality of clinical testing, we conducted an external quality assessment workshop with the participation of 31 laboratories.

MATERIALS AND

METHODS

Aliquots of pooled maternal plasma from gestational week 25 were sent to each laboratory. One sample was fetal RHD positive, and a second sample was fetal RHD negative. A reporting scheme was supplied for data collection, including questions regarding the methodological setup, results and clinical recommendations. The samples were tested blindly.

RESULTS

Different methodological approaches were used; 29 laboratories used qPCR and two laboratories used ddPCR, employing a total of eight different combinations of RHD exon targets. Fetal RHD genotyping was performed with no false-negative and no false-positive results. One inconclusive result was reported for the RHD positive sample. All clinical conclusions were satisfactory.

CONCLUSION

This external quality assessment workshop demonstrates that despite the different approaches taken to perform the clinical assays, fetal RHD genotyping is a reliable laboratory assay to guide targeted use of Rh prophylaxis in a clinical setting.

Для цитирования: Clausen Frederik Banch, Hellberg Åsa. External quality assessment of noninvasive fetal RHD genotyping.. Vox sanguinis. 2020. DOI: 10.1111/vox.12908.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.